Chengdu Ebyte Electronic Technology Co.,Ltd.
E95-DTU(900SLxx-485) User Manual
Copyright ©2012–2022
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
2
1
0
WOR cycle
Only valid for mode 1;
Period
T=
(1+WOR)*500ms,
the
maximum is 4000ms, and the minimum
is 500ms;
The longer the WOR monitoring interval
period, the lower the average power
consumption, but the greater the data
delay;
The sender and receiver must agree (very
important)
0
0
0
500ms
0
0
1
1000ms
0
1
0
1500ms
0
1
1
2000ms
1
0
0
2500ms
1
0
1
3000ms
1
1
0
3500ms
1
1
1
4000ms
07H
Writ
e
CR
YPT
_H
Key high byte (default 0)
write only, read returns 0;
Used for encryption to avoid interception
of air wireless data by similar radio
stations;
The radio will use these two bytes as a
calculation factor to transform and
encrypt the air wireless signal.
08H
Writ
e
CR
YPT
_L
key low byte (default 0)
80H
~
86H
Rea
d
PID
PID Product Information 7 bytes
PID Product Information 7 bytes
6.3 Factory default parameters
Mode
Factory default parameter value
:
C0 00 00 62 00 00
Radio model
Frequency
Addres
s
Channel
Air rate
baud rate
Serial
format
transmit
power
E95-DTU(900SLxx-48
5)
850.125M
Hz
0x000
0
0x17
2.4kbps
9600
8N1
22dBm (low
power)
30dBm (high
power)
Summary of Contents for E95-DTU