Chengdu Ebyte Electronic Technology Co.,Ltd
E95/E96-DTU(433Lxx-485)-V8 User_Manual_EN
Copyright ©2012–2022
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
7
the ground, use factory default parameters.
3.2 General parameter
No.
Terms
Specifications
Description
1
Size
92*66*30 mm
Review installation dimensions for details
2
Weight
95 g
Weight tolerance 5g
3
Working
Temperature
-40℃
~
+85℃
Meet the needs of industrial use
4
Voltage Range
8
~
28V
(
DC
)
85
~
265V
(
AC
)
12V or 24V recommended for DC version
110V/220V for AC version
5
Interface
RS485
RS485
6
Baud Rate
Default 9600
Baud rate range 1200
~
115200
7
Address Code
Default 0
A total of 65536 address codes can be set
3.3 Frequency range and channel number
Model
Default
Frequency
Frequency Range
Channel
Spacing
Number of Channels
Hz
Hz
Hz
E95/E96-DTU(433Lxx-485)-V8
433M
410
~
441M
1M
32
,
Half Duplex
Note: In the same area, multiple groups of digital DTUs are used for one-to-one communication at the same time. It is
recommended that each group of digital DTUs set the channel spacing above 2MHz.
3.4 Transmit power level
Model
20dBm / 30dBm
17dBm / 27dBm
13dBm / 24dBm
10dBm / 21dBm
E95/E96-DTU(433Lxx-485)-V8
Factory Default
√
√
√
★
Note: The lower the transmission power, the closer the transmission distance, but the working current will not decrease in the
same proportion. It is recommended to use the maximum transmission power.
3.5 Air data rate level
Model
Default Air Rate
Level
Air Data Rate Level
bps
bps
Summary of Contents for E95-DTU433L 485-V8 Series
Page 1: ...E95 E96 DTU 433Lxx485 V8 ...