Chengdu Ebyte Electronic Technology Co.,Ltd
ECAN-W01S User
Manual
Copyright
©2012–2022, Chengdu Ebyte Electronic Technology
Co.,Ltd
Subcontractin
g interval
(ms)
1
The value that can be filled in is 1~255. When
the CAN port does not receive new data frames
within the time defined by the "packet time
interval" (unit: ms) and the number of packet
frames has not been reached, all data frames
that have been received and have not been sent
before will be packaged into an Ethernet packet
and sent to the network port.
category
name
default
explain
CAN
configurat
ion
Standard frame
upper limit
7FF(HEX)
The upper limit and lower limit of the
received standard frame ID set by the
user jointly determine the standard
frame ID range to be received.
Lower limit of
standard frame
000(HEX)
Extended frame
upper limit
1FFFFFFF(HEX) The upper limit and lower limit of the
received extended frame ID set by the
user jointly determine the range of
extended frame IDs to be received.
Lower limit of
extended frame