10.
GAS CONVERSION
The gas conversion process (Natural Gas-LPG) involves replacing the gas
adjusting washer, adjusting gas pressure settings (capacity settings), and ad
-
justing the P01 service parameter. Natural gas and LPG parameter values are
given below. The diameter information and the last 3 digits of stock code will
be specified on the gas adjusting washer as marking (if there is no marking, it
should be specified with a colored pen).
10
.1. Gas Adjustment Table
Confeo Premix P
Minimum gas adjustment
Maximum gas
adjustment
Outlet
Inlet
Figure 13
Table
6
10
.2. Gas Pressure Adjustment
Please refer to "Chapter 12. Definitions of assembly/disassembly of the parts" section before starting
gas adjustment. Maximum and minimum gas pressure adjustment procedures are listed below.
DHW
Gas Ori
ffi
ce
P01
CH
Minimum
Capacity
Gas Type
Gas Ori
ffi
ce
Front Cover (Open) Front Cover (Close)
P39
(mm)
Code
Parameter Maximum Maximum
Fan Speed Fan Speed Fan Speed
Value
(rpm)
CO2 (Max/Min) (%) CO2 (Max/Min) (%) Parameter
(rpm)
(rpm)
Value
14 kW
DG
7,65±0,05
7006990320
0
6250
3800
1850
9,3±0,2 / 8,7±0,2
9,5±0,2 / 8,9±0,2
0
14 kW
LPG
6,5±0,05
7006990685
1
6100
3600
1850
10,4±0,2 / 9,7±0,2
10,6±0,2 / 9,9±0,2
0
20 kW
DG
7,65±0,05
7006990320
0
6250
5100
1850
9,3±0,2 / 8,7±0,2
9,5±0,2 / 8,9±0,2
0
20 kW
LPG
6,5±0,05
7006990685
1
6100
4900
1850
10,4±0,2 / 9,7±0,2
10,6±0,2 / 9,9±0,2
0
24 kW
DG
7,65±0,05
7006990320
0
6750
6250
1850
9,3±0,2 / 8,7±0,2
9,5±0,2 / 8,9±0,2
0
24 kW
LPG
6,5±0,05
7006990685
1
6600
6100
1850
10,4±0,2 / 9,7±0,2
10,6±0,2 / 9,9±0,2
0
28 kW
DG
7,9±0,05
7006990688
0
7000
6500
1900
9,3±0,2 / 8,7±0,2
9,5±0,2 / 8,9±0,2
2
28 kW
LPG
6,7±0,05
7006990689
1
6700
6200
1900
10,4±0,2 / 9,7±0,2
10,6±0,2 / 9,9±0,2
2
30 kW
DG
7,9±0,05
7006990688
0
7450
6900
2100
9,3±0,2 / 8,7±0,2
9,5±0,2 / 8,9±0,2
4
30 kW
LPG
7,1±0,05
7006990691
1
7400
6850
2100
10,4±0,2 / 9,7±0,2
10,6±0,2 / 9,9±0,2
4
35 kW
DG
8,1±0,05
7006990690
0
7600
7600
2300
9,3±0,2 / 8,7±0,2
9,5±0,2 / 8,9±0,2
6
35 kW
LPG
7,1±0,05
7006990691
1
7600
7600
2300
10,4±0,2 / 9,7±0,2
10,6±0,2 / 9,9±0,2
6
21
Summary of Contents for CONFEO PREMIX P 14 HM
Page 1: ...SERVICE MANUAL CONFEO PREMIX CONDENSING BOILER CONFEO PREMIX P 14 20 24 28 30 35 HM HCH HST...
Page 24: ...12 ELECTRICAL DIAGRAM Figure 15 24...
Page 34: ...Low Voltage Removing installing the pump cable FAN PWM CABLE Figure 39 Figure 40 34...
Page 52: ...Figure 76 Figure 77 52...
Page 83: ......