Remove the ignition-ionization screws using an Allen wrench.
Torque: 1 ± 0.2 Nm (Torx 4 mm)
Remove the 4 cover screws of the heat exchanger. When removing and installing the heat exchanger
cover, perform the operations according to the order written on the cover.
Torque: 5 ± 0.5
Figure 71
Figure 72
Figure 73
50
Summary of Contents for CONFEO PREMIX P 14 HM
Page 1: ...SERVICE MANUAL CONFEO PREMIX CONDENSING BOILER CONFEO PREMIX P 14 20 24 28 30 35 HM HCH HST...
Page 24: ...12 ELECTRICAL DIAGRAM Figure 15 24...
Page 34: ...Low Voltage Removing installing the pump cable FAN PWM CABLE Figure 39 Figure 40 34...
Page 52: ...Figure 76 Figure 77 52...
Page 83: ......