7- INSTALLATION
7.1 Selection of Location of Boiler
The boiler must be installed in accordance with gas safety regulations and relevant standards. Additionally,
the clearance around the boiler should be as shown in fig 10. In order to make service, maintenance and
usage easier.
Figure 10: It shows the minimum distances required from the top and sides of the boiler (Dimensions given
in mm).
The installation must comply with the following minimum distances so that servicing and maintenance of
the boiler can be performed correctly. The position of the boiler must be checked against technical
requirements.
Figure 10.Combi Mounting Clearances Figure 11.Isolation Valve Cover Mounting
CAUTIONS :
Do not install your boilers in locations that will be exposed to direct sunlight. Sunlight can
cause color change on the exterior of your boiler over time.
Ambient temperature of boiler's installation location should be between 5 -35
0
C.
The boiler can be used at altitudes up to 2000 m above sea level.
There is no need to remove side panels in the combi boiler service operations.
Minimum
50 mm clearances are given taking into consideration the share of possible side panel
sheet changes.
Since the outside temperature of the boiler
does not rise above 85 ° C at the maximum heating power, no
special protective measures are required against the combustible construction materials and components.
It is not recommended to install
“Isolating Valve Cover” (figure 11) to the
boiler if kitchen cupboard is used for installation place. It can be used at open
space areas to hide valve set and filling loop.