8 Orientation errors
User Manual
193
Error
Modules
The images
list of images
don't have enough matches with
their adjacent images. Please, remove or replace the
images. EyesMap cannot continue.
Point-to-Point
This error arises when not enough points are found to automatically orient the images being
processed. The process will stop. This can happen because the images do not have enough
overlapping or clarity. The process should be repeated, omitting the images listed or
substituting them with others which better align with the capture recommendations.
Error
Modules
Sorry, orientation could not take place. Images:
list of
images
don't have enough matches. Continue to exit.
Orthophoto
This error arises when not enough points are found to automatically orient the images being
processed. The process will stop. This can happen because the images do not have enough
overlapping or clarity. The process should be repeated, omitting the images listed or
substituting them with others which better align with the capture recommendations.
Warning
Modules
Warning: Sorry, the following images selected don't have
enough matches. We are going to delete them. Images:
list
of images
3D Photomodelling
This warning is shown when, for one or several non-consecutive images, enough common
points are not found to carry out orientation. EyesMap will delete these images from the 3D
reconstruction process.
Warning
Modules
Orientation may not be correct because the number of
points in common between images is less than optimal.
Anyway, the whole process will be completed.
Point-to-Point,
Orthophoto, 3D
Photomodelling
This warning is shown when, for one or several images, enough common points are not found
to carry out orientation. EyesMap can continue the process, but the quality of results
obtained is not certain.
Error
Modules
Orientation error. Please,
list of adjacent images
do not
have enough matches. Continue to exit."
3D Photomodelling
This error arises when not enough points are found to orient a group of adjacent images. This
can happen because the images do not have enough overlapping or clarity. If this happens
with the first images, no 3D model will be obtained. If this is not the case, you may obtain part
of the model generated with the main and secondary images which were selected before the
group that caused the error.
Error
Modules
Error. Orientation error. Please, check the overlap
between images.
Point-to-Point,
Orthophoto, 3D
Photomodelling
The images do not have enough overlap. Choose other captured images or take new images,
bearing in mind that the overlap between consecutive images should be, at minimum, 80%.
Summary of Contents for eyesmap
Page 1: ...USER MANUAL EYESMAP Version 1 0 Revision A June 2015...
Page 9: ...2 Technical Specifications In this chapter we shall see Tablet Cameras Depth Sensor GPS IMU 2...
Page 118: ...7 Practical cases User Manual 118 Medium Object...
Page 119: ...7 Practical cases User Manual 119 Small Object...
Page 120: ...7 Practical cases User Manual 120 7 1 1 2 Photo Development and Management...
Page 121: ...7 Practical cases User Manual 121 Small Objects...
Page 126: ...7 Practical cases User Manual 126 9 Orientation Points...
Page 129: ...7 Practical cases User Manual 129 Click on Confirm...
Page 130: ...7 Practical cases User Manual 130 The distance of the stereoTarget will be saved Click on Next...
Page 134: ...7 Practical cases User Manual 134...
Page 191: ...7 Practical cases User Manual 191...