SAVE THESE INSTRUCTIONS 

TESTED TO: EN13240 

 

CAUTION: HOT WHILE IN OPERATION.  DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND 

FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS  - SEE NAME PLATE AND INSTRUCTIONS 

THIS STOVE MUST BE INSTALLED IN CONJUNCTION WITH THE REQUIREMENTS OF BSEN 15287-

1:2007 

 DESIGN INSTALLATION AND COMMISSIONING OF CHIMNEYS. 

WARNING NOTE:  

Properly installed, operated and maintained this stove will not emit fumes into the dwelling.  
Occasional fumes from de-ashing and re-fuelling may occur.  However, persistent fume emission is 
potentially dangerous and must not be tolerated.  If fume emission does persist, then the following 
immediate action should be taken:- 

a)

 

Open doors and windows to ventilate the room and then leave the premises. 

b)

 

Let the fire go out. 

c)

 

Check for flue or chimney blockage and clean if required.  

d)

 

Do not attempt to relight the fire until the cause of the fume emission has been identified 
and corrected.  If necessary seek expert advice.  

The most common cause of fumes emission is flueway or chimney blockage.  For your own safety 
these must be kept clean at all times.  

A CO detector must be fitted in the same room as this appliance to conform to UK requirements of 
installation. 

The Clean Air Act 1993 and Smoke Control Areas 

Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a 

smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any 
fixed boiler if located in a designated smoke control area. It is also an offence to acquire an "unauthorised fuel" 
for use within a smoke control area unless it is used in an "exempt" appliance ("exempted" from the controls 
which generally apply in the smoke control area).  The Secretary of State for Environment, Food and Rural 
Affairs has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control 
areas in England. In Scotland and Wales this power rests with Ministers in the devolved administrations for 
those countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern Ireland. 
Therefore it is a requirement that fuels burnt or obtained for use in smoke control areas have been "authorised" 
in Regulations and that appliances used to burn solid fuel in those areas (other than "authorised" fuels) have 
been exempted by an Order made and signed by the Secretary of State or Minister in the devolved 
administrations. Further information on the requirements of the Clean Air Act can be found here : 

http://smokecontrol.defra.gov.uk/

Your local authority is responsible for implementing the Clean Air Act 1993 

including designation and supervision of smoke control areas and you can contact them for details of Clean Air 
Act requirements 

The Ecco Stoves 580EC2 has been recommended as suitable for use in smoke control areas 

when burning wood logs with a maximum moisture content of  20%

” seasoned wood logs only

 

Summary of Contents for 580EC2

Page 1: ...he Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace...

Page 2: ...AIR e RELIGHTING WITH OUTSIDE AIR f CLOSING DOWN g FLUE DAMPER 12 FIRING THE STOVE 1 COMISSIONING AND HANDOVER a INITIAL FIRING b SUBSEQUENT FIRING c REFUELING AFTER STARTING d OVER FIRING WARNING e...

Page 3: ...g e 3 of 29 Ecco Stove Foster House 2 Redditch Road Studley B80 7AX United Kingdom T 44 0 1527 857 814 E sales eccostove com W www eccostove com For all patents See Addendum 27 WARRANTY REGISTRATION 2...

Page 4: ...www eccostove com For all patents See Addendum ADDENDUM Patents United Kingdom 2 213 945 E 2 467 433 United States 10 627 112 9 523 505 Canada 2 691 409 Germany 60 2010 064 710 2 Belgium 2 213 945 E S...

Page 5: ...of the chimney to be used must be checked before installation not all chimneys are suitable The Ecco Stove 580EC2 is tested for use with wood logs you must check with your local area authority to ens...

Page 6: ...It is deemed a consumable item and is not covered by the warranty When replacing the glass ensure that the screws retaining the glass clips are tightened to hand tight only as over tightening will cra...

Page 7: ...7 in place 9 ROPE SEALS Rope seals will deteriorate When worn or flattened such that they do not make a satisfactory seal replace the rope seal with 8mm ceramic rope but ensure the indent within the...

Page 8: ...the stove reaches its minimum optimum operating temperature of 150 C on the top plate c SECONDARY AIR introduced from the rear of the stove front spinner is closed Secondary air is automatically fed i...

Page 9: ...ated with air controls appliance dampers or door left open except as directed in the instructions 12 FIRING THE STOVE 1 Commissioning Ensure all parts are fitted in accordance with these installation...

Page 10: ...not A raging lively fire will be seen which is ideal Run as such until the stoves top is up to minimum 160 C maximum 200 C Refuelling on a low fire bed If there is insufficient burning material in the...

Page 11: ...s possible ensure the ash pit drawer is fully closed b SUBSEQUENT FIRING Re starting the stove after its initial firing should be carried out with the ash pit cleared out and the ash pit drawer open 1...

Page 12: ...for emptying but ensure it is re fitted to follow the lighting procedure at 13a in this manual 15 FUELS Wood as a fuel should be up to 20 moisture content using split logs 75mm in diameter for best co...

Page 13: ...ey are highly combustible Creosote build up must be removed to prevent a fire hazard within the chimneys flue Tar deposits will not form if seasoned logs of up to 20 moisture are burned at 160 C or ab...

Page 14: ...FIRE THE FLUE MUST BE SWEPT AGAIN WITHIN A MONTH OF INSTALLATION AS THE HIGHER TEMPERATURE OF FLUE GASES MAY LOOSEN THE OLD OPEN FIRES BUILT UP DEPOSITS TO ENSURE BLOCKAGE DOESN T OCCUR 19 CLEANING A...

Page 15: ...distorted and closed The catalyser will gather dust and needs checking cleaning monthly Each month or so remove the pins and lower the underside baffle vacuum the catalytic honeycomb catalyser carefu...

Page 16: ...rts one door and frame including glass cast iron grate 2 x back baffle boards 2 x inner left and right cheeks two spacer blocks and two horizontal baffles Ancillary parts and one pair of gloves for op...

Page 17: ...wn to bed in d Back Panel Fit the back panel between the sides it may help to spread the sides a little at their tops to easily fit the back in Ensure the circular Tertiary hole is towards the bottom...

Page 18: ...off the stoves back panel Stand the left and right Silicon Carbide and inner side cheeks inside the stove against the side sections with the tapered edge against the back board These inner side cheek...

Page 19: ...ed edge facing up sharp edge against the underside of the doors frame located over the middle level 4 pins using the two rear indents to locate the baffle Locate the Silicon Carbide baffle block in to...

Page 20: ...al hearth capable of bearing this weight c Air Supply 9 sq centimetres required within the UK Refer to ADJ2010 Outside the UK to those countries of local area requirements d Extractor Fans No extracto...

Page 21: ...changes may be made by the manufacturer without notice c Replacements must only be of the manufacturers supply and design CO Alarms Building regulations require that whenever a new or replacement fix...

Page 22: ...ing Fire cement certain products and fire cements are caustic when in contact with skin Always use protective gloves when handling and wash skin immediately if contact with the skin is made Asbestos T...

Page 23: ...can NBW1 1 Steel rod trigger TR5 1 Rope seal 8mm x 1400 mm long RS1 1 Flat tape seal FT1 1 Glass ladder back tape seal L 6mmx1260mm LBT1 KT653 1 Vermiculite spacer block SP5 1 Vermiculite Back Board V...

Page 24: ...th the stove pipes damper if fitted closed to slowly release heat into the house on a falling heat Should it be preferred this heat is later topped up a fresh fuelling may be undertaken and initial fi...

Page 25: ...er h Rope seals Door 8mm x 1450 long Glass 6mm flat x 1290 long Rear baffle top 12mm x 430 Ecco Stove 580EC2 Description Value Nominal Heat Output 7 0 Net Efficiency 80 4 Particulate emissions 13 O2 m...

Page 26: ...of installation see last page 3 Warranty Period Silicon Carbide parts are warranted for 10 years from the date of purchase the date purchased from the Company Surface hairline cracks internally to th...

Page 27: ...finishes will change colour with use This warranty does not cover such changes 8 Fuels The warranty only applies to the use of wood logs on your Ecco Stove 580EC2 Coals or processed petro chemical fue...

Page 28: ...BY ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER INSTALLERS REGISTERED BODY AND NUMBER DATE THE ECCO STOVE WAS INSTALLED SELLING AGENT DEALER COMPANY NAME ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER...

Page 29: ...lake on the stoves outer body This typically occurs after re firing when the stove has periods without use during the colder weather or when building works such as fresh plaster have taken place in an...

Reviews: