580/03.05.23/V2
P a g e |
20
of 29
Ecco Stove | Foster House | 2 Redditch Road | Studley | B80 7AX | United Kingdom
T
| +44 (0) 1527 857 814
E
W
| www.eccostove.com
For all patents
–
See Addendum
22.
HEARTH CONSTRUCTIONAL
a)
Your Ecco Stove 580EC2 must stand on a constructional hearth of non-combustible
materials capable of carrying 270kg with an overall width of 880mm (UK) minimum and
an overall depth of 800mm (UK) minimum which allows/includes 75mm gap for the
stove off the rear non combustible wall (200mm to a combustible wall) to accommodate
the rear air control.
These dimensions must be checked for local or in country requirements.
b)
HEARTH (DECORATIVE)
Must extend 150mm either side and 300mm in front as a minimum (or differently if in
country or local regulations dictate).
THE STOVE MAY NOW BE LIT
23.
TECHNICAL
Heating appliance EN13240
a)
Outputs
b)
Weight: Complete appliance = 270kg: the Ecco Stove 580EC2 must be installed onto a
structural hearth capable of bearing this weight.
c)
Air Supply
–
9 sq centimetres required within the UK (Refer to ADJ2010)
Outside the UK to those countries of local area requirements.
d)
Extractor Fans: No extractor fans are to be fitted into the same room as the Ecco Stove.
e)
Flue Draught: Minimum cold flue 10 pascals
f)
Flue gas mass flow: 5.6
g)
Flue gas temperature: Average °C at nominal output.
h)
Flue Outlet: 150mm top exit only (dampers are necessary if the flue draught is in excess
of 15 pascals water gauge or for slow heat release) from the stove.
i)
Heat Stored: typically 30% after 4 hours (subject to flue draught)
j)
CO Concentration at 13% oxygen 0.08
Excessive flue draught may remove too much heat from the Ecco Stove 580EC2 on slow
combustion. A damper may be fitted into the flue pipe off the stove to reduce the flues
draught; but only closed after the stoves burning process is completed
–
dampers must
always allow or leave 20% of flues area when closed.
A CO-DETECTOR MUST BE FITTED IN THE SAME ROOM AS THIS APPLIANCE TO CONFORM
TO UK REQUIREMENTS OF INSTALLATION
k)
Efficiency 80.5%
l)
Minimum distances to combustibles:
Rear 250mm
Sides and top 300mm