background image

die  lust  am  hören

Marketing - Dienstleistung - Schnellhörtester - Hörgeräte-Servicetools

 

e

ccola

 

 
 

page 9 of  9 

 

 

 

 

 

 

                  Update April 2022 

 

 

die  lust  am  hören

Marketing - Dienstleistung - Schnellhörtester - Hörgeräte-Servicetools

 

 

 

                         

 

 

 

 

 

 

 

 

 

 

Contact:

 

 

 

Im Alber 8 - D-73084 Salach 

Tel.: +49 7162 - 94 899 6 - Fax:  +49 7162 – 94 899 7 

Email: 

info@eccola.de

 – Internet: 

www.eccola.de

  

 

Summary of Contents for ecco cleaner

Page 1: ...ie lust am h ren Marketing Dienstleistung Schnellh rtester H rger te Servicetools eccola page 1 of 9 Update April 2022 Instruction Manual for the Hearing Aids Drying and Cleaning Equipment ecco cleane...

Page 2: ...2 Use 3 3 Technical Data 3 4 Startup Main Switch 3 5 Delivery Transport Regulations Installation Instructions 4 6 Cleaning of Receiver and Microphone of the Hearing Aids 4 7 Drying of Hearing Aids 5...

Page 3: ...rofuse 5 x 20 mm 5 A delay action Protection class IP 21 Dimensions L x W x H 260x220x240 mm Weight about 7 kgs 4 Startup Main Switch Plug the delivered power cord on the back side and set the main sw...

Page 4: ...because of eventual excess pressure in the cylinder power cord and instruction manual 6 Cleaning of Receiver and Microphone of the Hearing Aids Before cleaning and drying the hearing aids we recommend...

Page 5: ...Put the hearing aid max 2 hearing aids on the rubber pad and put the drying cup on top Suggestion Prior to that remove the support hook and or all filter systems The hearing aid should not be placed...

Page 6: ...ne at least once a month the same can be supplied by us The support of the filter is preferably cleaned by means of a vacuum cleaner Please make sure that the filter is firmly attached and that the bl...

Page 7: ...atures of cleaning are achieved by a control technology specifically developed for this purpose No function of the orange coloured power light emitting diode on the front side of the equipment Check e...

Page 8: ...93 68 EEC EC directive of electromagnetic compatibility 96 336 EEC Applied standards EN 55011 EN 61000 6 2 EN 61000 3 2 EN 61000 3 3 In the event of illegitimate modifications improper repairs or cha...

Page 9: ...rger te Servicetools eccola page 9 of 9 Update April 2022 die lust am h ren Marketing Dienstleistung Schnellh rtester H rger te Servicetools Contact Im Alber 8 D 73084 Salach Tel 49 7162 94 899 6 Fax...

Reviews: