GB
8
•
Default RF: CHANNEL 1
RF reception
•
After inserting the batteries, the temperature and humidity test starts,
RF reception starts automatically for 3 minutes, the antenna icon flashes
at a frequency of 1 Hz.
•
Hold down the "CH" button for 2 seconds to clear the channel data and
receive new ones.
RCC reception (time):
Request for RCC reception:
•
Start or after reset, RCC reception will start after 3 minutes.
•
Hold down the "DOWN" button for 2 seconds to force RCC reception.
•
Automatic daily reception
RCC reception time: 7 minutes
RCC auto reception time: 1:00, 2:00, 3:00. If received at 3:00, no further
reception is started, if not, reception starts again at 4:00, 5:00, if received at
5:00, no further reception is started.
RCC reception icon:
•
When an RCC signal is received, the tower portion of the RCC icon flashes
at a frequency of 1 Hz.
•
If the signal is weak or not recognized, the icon also flashes at a frequency
of 1 Hz.
•
After successful reception, the RCC icon will be displayed at rest.
During RCC reception, you can end the mode by holding down the "DOWN"
button for 2 s; press the "SNZ" button to switch on the lighting; the other
buttons do not work.
•
If no signal is received one day, another attempt will be made the next
day at 1:00.
•
If an alarm is activated during RCC reception, RCC reception is terminated.
•
When a DST signal is received, the DST icon is displayed.
•
After setting the new time, the RCC icon turns off.
Temperature monitoring function:
•
The default settings of the temperature monitoring function are + 70 °C
for high temperature and -50 °C for low temperature.