GB
9
•
When the set limits are exceeded, the corresponding temperature and
the alarm symbol flash.
•
If the alarm is not currently displayed on the channel, only the alarm
symbol flashes and the temperature does not flash.
•
Sound signaling of the temperature monitoring function:
•
Beeping 3× per second
•
5 s per minute, 55 seconds quiet
•
If the temperature returns to the range, the alarm ends.
•
Stopping alarm:
•
Press any button The sound is muted, the temperature and the
symbol still flash.
•
The symbols stop automatically when the temperature returns
within the range.
•
You can turn off the function in the "ALERT" setting mode.
Thermal comfort and trend indication
•
If the difference between the current and saved temperature e
1 ° C, the temperature trend will increase.
•
If the difference between the current and saved temperature exceeds -1
° C, the temperature trend will decrease.
Indication of thermal comfort:
•
Drought: any temperature, humidity below 40%
•
Comfort: temperature between 20-28 ° C, humidity between 40-70%
•
Humidity: any temperature, humidity over 70%
•
No indication: temperature is not in the range of 20-28 ° C, humidity 40-
70%, no indication.
Weather forecast function:
•
Weather station: next 24 hours and weather trend
•
4 weather conditions: sunny, partly cloudy, overcast, precipitation
•
The accuracy of the forecast data depends on the degree of ventilation
of the room, in air-conditioned rooms the error can be large.
WEATHER STATION MAINTENANCE
1. Do not expose the device to extreme temperatures, direct sunlight, or
liquids.