 ECHO TEC. WATERMAKER LIMITED WARRANTY 

 
Echo Marine Ltd. warrants to the original purchaser for a period of twelve (12) months from the date of 
shipment  that  the  ECHO  Tec.  watermaker  will  perform  according  to  specifications.    Echo  Marine’s 
liability under this warranty shall be limited to repair or replacement of the ECHO Tec. watermaker at 
Echo  Marine’s  option.  Under  no  circumstances  shall  Echo  Marine  Ltd.  be  liable  for  consequential 
damages  arising  out  of  or  in  any  way  connected  with  the  failure  of  the  system  to  perform  as  set  forth 
herein.  This limited warranty is in lieu of all other expressed or implied warranties, including those of 
merchantability and fitness for a particular purpose. 
 
 
In the event of a defect, malfunction, or failure during the warranty period, Echo Marine Ltd. will repair 
or  replace,  at  its  option,  the  product  or  component  therein  which,  upon  examination  by  Echo  Marine, 
shall appear to be defective, or not up to factory specifications. 
 
 
To  obtain  warranty  service,  the  defective  product  or  part  must  be  returned  to  Echo  Marine’s  Service 
Center.  The purchaser must pay any transportation or labor expenses incurred in removing and returning 
the product to the service center. 
 
 
The  limited  warranty  does  not  extend  to  any  system  component  which  has  been  subjected  to  misuse, 
neglect, accident, improper customer installation, or used in violation of instructions furnished by Echo 
Marine Ltd.  The warranty does not extend to components on which the serial number has been removed, 
defaced or changed. 
 
 
Echo Marine Ltd. reserves the right to make changes or improvements in its product during subsequent 
production  without  incurring  the  obligation  to  install  such  changes  or  improvements  on  previously 
manufactured equipment. 
 
 
The implied warranties, which the law imposes on the sale of this product, are expressly  LIMITED, in 
duration  to  the  time  period  above.    Echo  Marine  shall  not  be  liable  for  damages,  consequential  or 
otherwise,  resulting  from  the  use  and  operation  of  this  product  or  from  the  breach  of  this  LIMITED 
WARRANTY. 
 
This limited warranty service does not apply to normal recurring user maintenance as described below. 
 
 

  Pre-filter Cartridges    

 

  Pump Valve Assemblies 

 

  Pump Seals   

 

 

  Gauge Instrument Calibration 

 

  Pump Packings 

 

 

  Pump Crankcase Oil 

 

   

           

Summary of Contents for 1000-BHL- 2

Page 1: ...ES 5 6 INSTALLATION INSTRUCTIONS 7 8 OPERATION INSTRUCTIONS 9 MEMBRANE CLEANING PROCEDURE 10 MAINTENANCE TIMETABLE 11 PRESSURE VESSEL ENDPLUG CHANGING PROCEDURE 12 ELECTRICAL DIAGRAM 13 TROUBLESHOOTIN...

Page 2: ...familiar with each component of your new ECHO Tec desalination system By understanding the function importance and normal operation of each part in the system the operator can readily diagnose proble...

Page 3: ...FC Polyamide thin film composite spiral wound single pass reverse osmosis element SALT REJECTION min 99 5 SALINITY RANGE up to 33 000 ppm TDS NaCl PH RANGE 4 11 CHLORINE TOLERANCE 1000 ppm hours OPERA...

Page 4: ...316SS glycerin filled Flow Meter Product discharge Conductivity Digital product water quality monitor ppm TDS The following automatic emergency shut off functions are provided Low feed water pressure...

Page 5: ...cation inhibits growth of algae Connect the intake of the feed pump and the outlet of the priming reservoir with 3 4 PVC pipe or directly if possible Avoid elbows 90 degree fittings in your plumbing T...

Page 6: ...rinated water from your storage tanks sucks back into the RO membranes Therefore lead the product water into the tanks above water level The Product water can be led to the storage tanks up to a heigh...

Page 7: ...electrical control panel to the FEED position feed pump only and purge the system until all entrapped air has escaped 4 In the AUTO position press the START button until the pressure on the low press...

Page 8: ...r for more than ten days growth of microorganism will degrade the RO membranes performance The RO membranes should be flushed with a biocide solution to preserve the membrane for long term storage of...

Page 9: ...on label CAUTION Do not mix different cleaning chemicals together Do not use different cleaning chemicals together at the same time Mix the cleaning chemicals separately and use them separately Note...

Page 10: ...6 months High pressure pump Change crankcase oil Change packings seals and O rings Initial change after 50 hrs Every 200 operating hours or 6 months Every 5000 hrs or 2 years R O membrane When produc...

Page 11: ...s inner wall and remove it in one fast pull 6 Inspect the end plug for hairline cracks or damages on the O rings and O ring grooves 7 Pull the membrane on the product pipe out of the pressure vessel...

Page 12: ...TRANS FORMER START SWITCH S1 PUSH BUTTON NO SELECTOR SWITCH S2 3 POSITION MAINT 4 CONTACTS NO T1 HIGH PRESS SWITCH S4 NC LOW PRESS SWITCH S5 NO TANK FULL SWITCH S6 NC EXTERNAL MAIN IN ELECTRICAL DIAG...

Page 13: ...inlet lines for restrictions Check strainer and filter s Inability to Discharge valve chamber Allow more time to prime build up pressure has air trapped within it and ensure that there are no air suct...

Page 14: ...wn on page 8 Inspection inlet outlet valves 2 1 Remove valve caps slide out inlet outlet valves check the sondition of the various components of the valve and well as the O Ring replace if necessary 2...

Page 15: ...lacing oil seals 6 1 Remove the head See remove the ceramic pistons discharge oil 6 2 Remove the oil seals and the O Rings checking the seats and the piston guides 6 3 Remove the rear cover gasket 6 4...

Page 16: ...ned to Echo Marine s Service Center The purchaser must pay any transportation or labor expenses incurred in removing and returning the product to the service center The limited warranty does not exten...

Page 17: ...ranteed against iron fouling rust chemical attack extreme temperatures over 113 F under 33 F drying out or extreme pressures over 1000 psig CAUTION Use of parts not supplied directly by Echo Marine ge...