FUEL
Fuel Requirements
Gasoline - Use 89 Octane [ ] (mid-grade or higher) gasoline or
gasohol known to be good quality. Gasohol may contain up to 10%
Ethyl (grain) alcohol or 15% MTBE (methyl tertiary-butyl ether). Gasohol
containing methanol (wood alcohol) is NOT approved.
Two Stroke Oil - A two-stroke engine oil meeting ISO-L-EGD Standard
(ISO/CD 13738), must be used. Echo brand Premium 50:1 oil meets this
standard. Engine problems due to inadequate lubrication caused by
failure to use an ISO-L-EGD approved oil, such as Echo Premium 50:1
Two-stroke Oil, will void the two-stroke engine warranty. (Emission
related parts only are covered for two years, regardless of two-stroke oil
used, per the statement listed in the EPA Phase I/California Emission
Defect Warranty Explanation.)
Mixing - Follow directions on the oil container.
Handling Fuel
WARNING DANGER
Fuel is VERY flammable. Use extreme care when mixing, storing or
handling or serious personal injury may result.
• Use an approved fuel container.
• DO NOT smoke near fuel.
• DO NOT allow flames or sparks near fuel.
• Fuel tanks/cans may be under pressure. Always loosen fuel caps
slowly allowing pressure to equalize.
• NEVER refuel a unit when the engine is HOT!
• NEVER refuel a unit with the engine running.
• DO NOT fill fuel tanks indoors. ALWAYS fill fuel tanks outdoors
over bare ground.
• Securely tighten fuel cap after refueling.
• Inspect for fuel leakage. If fuel leak is found, do not start or operate
unit until leak is repaired.
After Refueling;
• Wipe any spilled fuel from the unit.
• Move at least 3M (10 ft.) from refueling location before starting.
After Use;
• DO NOT store a unit with fuel in its tank. Leaks can occur. Return
unused fuel to an approved fuel storage container.
Storage
Fuel storage laws vary by locality. Contact your local government for
the laws affecting your area. As a precaution, store fuel in an approved,
air tight container. Store in a well ventilated, unoccupied building, away
from sparks and flames. Do not store fuel longer than 30 days.