OPERATION
HCS-3020 4020
20
X7702243800
© 3/2016 ECHO Inc.
Move stop switch (A) away from the
STOP position.
2.
Choke
Move choke (B) to COLD START
(
) (CLOSED) position.
3.
Purge Bulb
Pump purge bulb (C) until fuel is
visible and flows freely in the clear
fuel tank return line. Pump bulb an
additional 4 or 5 times.
4.
Recoil Starter
Lay the unit on a flat, clear area.
Grip the support handle securely
with right hand, and pull the recoil
starter handle (D) with left hand until
engine fires (or 5 pulls maximum).
5.
Choke
After engine fires (or 5 pulls), move
choke (B) to the RUN (
)
(OPEN) position. Restart engine if
necessary and allow unit to warm
up at idle for several minutes.
Note: If engine does not start with
choke in “RUN” position after
5 pulls, repeat instructions 2
- 5.
The blades must not move at idle, otherwise serious personal
injury may result. Periodic carburetor adjustment may be
necessary to assure blades do not move at idle. If blades move,
readjust carburetor according to “Carburetor Adjustment”
instructions in this manual or see your Dealer.
6.
Throttle Trigger
C
B
D
D