PB-251
FUEL SYSTEM
26
5-1 Cleaning air filter
1. Close choke shutter and remove air cleaner cover
and air filter.
2. Clean air cleaner cover and air filter with com-
pressed air or wash air filter in a suitable cleaning
solvent. Air filter should be dried completely after
washing.
WARNING DANGER
Wear an eye protection when working with
compressed air. Eye damage can occur from
flying particles.
3. Replace air filter if heavily soiled or defective.
5-2 Checking fuel cap and fuel strainer
1. Remove fuel cap.
2. Check fuel cap for cracks and gasket (A) for cuts
or damage. Replace defective parts as required.
3. Pull fuel strainer (B) from fuel tank using a wire
hook and replace with a new one if it is blocked with
dirt.
4. Reinstall fuel cap.
(A)
(B)
Summary of Contents for PB-251
Page 1: ...Ord No 403 16...