13
P
OWER
B
LOWER
O
PERATOR
'
S
M
ANUAL
STARTING
WARM
ENGINE
The starting procedure is the same as Cold Start except DO NOT close
the choke.
1.
Throttle Lever
Move throttle lever (A) to start/idle detent position.
2.
Primer
Pump primer bulb (C) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
3.
Recoil Starter
Pull recoil starter handle (D) and engine should start.
NOTE
If engine does not start after 5 pulls, use cold start procedures.
STOPPING
ENGINE
1.
Throttle Lever
Move throttle lever (A) to idle detent position and allow engine to
return to idle before shutting off engine.
2.
Move throttle lever (A) to "O" (Stop) position.
WARNING
DANGER
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using blower
again.
A
A
D
RUN
COLD
START
B
C