13
P
OWER
B
LOWER
O
PERATOR
'
S
M
ANUAL
STARTING
WARM
ENGINE
1. Move throttle lever (A) forward to idle position.
2. Slide stop switch (B) forward to run position. Pull recoil starter
handle (C) and engine should start. Do not use choke (D)
NOTE
If engine does not start after 5 pulls, use cold start procedures.
STOPPING
ENGINE
1. Move throttle lever (A) forward to idle position. Allow engine to
return to idle before shutting off engine.
IMPORTANT
Allow engine to return to idle before shutting off engine.
2. Move stop switch (B) to "Stop" position.
WARNING
DANGER
If engine does not stop when stop switch is moved to STOP
position, close choke - COLD START position - to stall engine.
Have your ECHO dealer repair stop switch before using blower
again.
C
D
B
A
B
A
Summary of Contents for PB-750
Page 22: ...22 NOTES...