STARTING
COLD
ENGINE
• Recoil starter: Use short pulls - only 1/2-2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold the unit
firmly.
PB-755H
1.
Throttle Lever
Move throttle lever (A) to IDLE DETENT position.
PB-755T
1.
Throttle Lever/Stop Switch
Move throttle lever (A) forward to idle position. Slide stop switch
(B) forward to run position.
PB-755H, PB-755T
2.
Choke
Move choke (C) up to "Cold Start" position (
).
3.
Purge Bulb
Pump purge bulb (D) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
4.
Recoil Starter
Pull recoil starter handle (E) until engine fires (5 or 6 pulls maxi-
mum).
5.
Choke
Move choke (C) down to run position (
), and if necessary,
restart engine.
NOTE
If engine does not start after 5 pulls, move choke to "Cold Start"
position, and repeat steps 4 & 5.
NOTE
Allow engine to warm up before use.