background image

wheeled trimmer

13

ENGLISH

  

 

 

 

SPECIFICATIONS

7.2   boLT ToRQuE

The tables below are for reference purposes only and their use by anyone is entirely voluntary, unless otherwise noted. 

Reliance on their content for any purpose is at the sole risk of that person and any loss or damage resulting from the 

use of this information is the responsibility of that person.

boLT dIamETER (a)

ENGLISH

boLT ToRQuE *

SaE 2

SaE 5

SaE 8

N.m

Ft-lb.

N.m

Ft-lb.

N.m

Ft-lb.

1/4”

7.5

5.5

11

8

16

12

5/16”

15

11

23

17

34

25

3/8”

27

20

41

30

61

45

7/16”

41

30

68

50

95

70

1/2”

68

50

102

75

149

110

9/16”

97

70

149

110

203

150

5/8”

122

90

203

150

312

230

3/4”

217

160

353

260

515

380

7/8”

230

170

542

400

814

600

1”

298

220

786

580

1220

900

1-1/8”

407

300

1085

800

1736

1280

1-1/4”

570

420

2631

1940

2468

1820

boLT dIamETER 

(a)

mETRIc

boLT ToRQuE *

4.8

8.8

10.9

12.9

N.m

Ft-lb.

N.m

Ft-lb.

N.m

Ft-lb.

N.m

Ft-lb.

M3

0.5

0.4

-

-

-

-

-

-

M4

3

2.2

-

-

-

-

-

-

M5

5

4

-

-

-

-

-

-

M6

6

4.5

11

8.5

17

12

19

14.5

M8

15

11

28

20

40

30

47

35

M10

29

21

55

40

80

60

95

70

M12

50

37

95

70

140

105

165

120

M14

80

60

150

110

225

165

260

190

M16

125

92

240

175

350

255

400

300

M18

175

125

330

250

475

350

560

410

M20

240

180

475

350

675

500

800

580

M22

330

250

650

475

925

675

1075

800

M24

425

310

825

600

1150

850

1350

1000

M27

625

450

1200

875

1700

1250

2000

1500

*   Torque value for bolts and capscrews are identified by their head markings.
Torque figures indicated above are valid for non-greased or non-oiled threads and heads unless otherwise specified.  Therefore, do not 

grease or oil bolts or capscrews unless otherwise specified in this manual.  When using locking elements, increase torque values by 5%.

SAE - 8

SAE - 2

A

SAE - 5

SAE

Grade

and

Head

Markings

BOLT DIAMETER

Summary of Contents for WT160S

Page 1: ...panion to 12330 SN Range 702557 A05369 wheeled trimmer WT160S 160 cc SELF PROPELLED WT160T 160 cc push W TILT WT190 190 cc push WT190S 190 cc self propelled WT190T 190 cc push W TILT WT190SE 190 cc SE...

Page 2: ...reet P O Box 849 West Fargo ND 58078 800 247 7335 701 282 5520 Fax 701 282 9522 opesales crary com service crary com Monday Friday 8 am to 5 pm Central Time SERIAL NUMBER MANuFACTuRED By CRARy INDuSTR...

Page 3: ...t not limited to bearings belts pulleys filters 2 and chipper knives This warranty does not cover normal maintenance service or adjustments 3 This warranty does not cover depreciation or damage due to...

Page 4: ...arting the mower 7 4 2 Stopping the mower 7 4 3 trimming Guide 7 4 4 self propelled operation 8 4 5 Parallel Trimming for push trimmers 8 4 6 parallel Trimming for self propelled models 8 4 7 Off Cent...

Page 5: ...ch a manner that flames or heat from the system will not ignite flammable material Failure of the owner operator of the equipment to comply with this regulation is a misdemeanor under California law a...

Page 6: ...servicing storing or changing 1 an accessory shut off the machine and make sure all moving parts have come to a complete stop Disconnect the battery and remove the ignition key where applicable Replac...

Page 7: ...PLUG WIRE FROM SPARK PLUG AND MAKE SURE ALL MOVING PARTS HAVE COME TOACOMPLETE STOP DO NOT OPERATE THIS EQUIPMENT IN THE VICINITY OF BYSTANDERS DO NOT A L L O W C H I L D R E N TO OPERATE THIS EQUIPM...

Page 8: ...ndlebar Rotate the container and attach the remaining end to the opposite side of the handlebar using one 5 16 x 2 1 4 bolt washer and nut DO NOT TIGHTEN BOLTS AT THIS TIME Stand handlebar upright Ali...

Page 9: ...s away from sparks or flames Acontainer with a capacity of 2 gallons or less with a pouring spout is recommended Do not fill the fuel tank while the engine is hot or running since spilled fuel could i...

Page 10: ...when starting a cold engine Firmly push the primer bulb 3 times before starting self propelled bail Models All self propelled models Engages the self propel mode Pull up the self propel bail located...

Page 11: ...throttle 7 lever if equipped from the CHOKE position to the RUN position Move the throttle if equipped to the SLOW position 1 then release the trimmer bail OR move the throttle to the STOP position Cl...

Page 12: ...rd to the original position Tighten the right axle bolt and resume regular trimming 5 or mowing Models All self propelled models The Wheeled Trimmer can be used in either push or self propelled mode P...

Page 13: ...orrective action taken This schedule is designed for units operating under normal conditions If the unit is operating in adverse or severe conditions it may be necessary for the items to be checked an...

Page 14: ...hole used in Step 1 Pull the cutting string tight Loop the cutting string back and feed through the first 3 hole on the opposite end of the trimmer head Feed through the remaining second hole and pul...

Page 15: ...e is obstructed 4 Dirty stale water 5 contaminated gas Flooded engine 6 Dirty or plugged air cleaner or 7 engine cooling fins Trimmer bail not engaged 8 Fill gas tank 1 Connect loose wire to the spark...

Page 16: ...lbs 77 lbs OVERALL LENGTH 50 50 50 50 50 50 OVERALL HEIGHT 38 38 38 38 38 38 OVERALL WIDTH 21 21 21 21 21 21 FRAME MATERIAL Solid steel Solid steel Solid steel Solid steel Solid steel Solid steel HAN...

Page 17: ...1 4 570 420 2631 1940 2468 1820 BOLT DIAMETER A METRIC BOLT TORQUE 4 8 8 8 10 9 12 9 N m Ft lb N m Ft lb N m Ft lb N m Ft lb M3 0 5 0 4 M4 3 2 2 M5 5 4 M6 6 4 5 11 8 5 17 12 19 14 5 M8 15 11 28 20 40...

Page 18: ...se of harmonized standard EN ISO 3744 2010 Sound Power Level 84 dB LPA Guaranteed Sound Power Level 98 dB LWA WT160S Serial number 703605 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES...

Page 19: ...f harmonized standard EN ISO 3744 2010 Sound Power Level 84 dB LPA Guaranteed Sound Power Level 98 dB LWA WT160SXE Serial number 703605 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES IN...

Page 20: ...Use of harmonized standard EN ISO 3744 2010 Sound Power Level 84 dB LPA Guaranteed Sound Power Level 98 dB LWA WT160SXS Serial number 703605 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRI...

Page 21: ...se of harmonized standard EN ISO 3744 2010 Sound Power Level 84 dB LPA Guaranteed Sound Power Level 98 dB LWA WT160T Serial number 700825 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES...

Page 22: ...f harmonized standard EN ISO 3744 2010 Sound Power Level 84 dB LPA Guaranteed Sound Power Level 98 dB LWA WT160TXE Serial number 700825 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES IN...

Page 23: ...Use of harmonized standard EN ISO 3744 2010 Sound Power Level 84 dB LPA Guaranteed Sound Power Level 98 dB LWA WT160TXS Serial number 700825 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRI...

Page 24: ...se of harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190 Serial number 707258 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES...

Page 25: ...harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190XE Serial number 707258 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES INC...

Page 26: ...se of harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190XS Serial number 707258 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIE...

Page 27: ...se of harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190S Serial number 702033 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES...

Page 28: ...harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190SXE Serial number 702033 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES IN...

Page 29: ...se of harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190SXS Serial number 702033 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRI...

Page 30: ...se of harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190T Serial number 700096 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES...

Page 31: ...harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190TXE Serial number 700096 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRIES IN...

Page 32: ...se of harmonized standard EN ISO 3744 2010 Sound Power Level 87 dB LPA Guaranteed Sound Power Level 101 dB LWA WT190TXS Serial number 700096 and up West Fargo ND 58078 0849 June 29 2011 CRARY INDUSTRI...

Reviews: