Echoflex Installation Guide

ElahoAccess Interface

2.

Connect Interface ESD ground wire pigtail.

a.

Strip 7/16” (11 mm) of insulation from the ends of the Interface
ground wire pigtail, provided in the termination kit, and the
incoming ground wire.

b.

Use one WAGO 221 Series LEVER-NUTS

®

, provided in the

termination kit, to connect the Interface ESD ground pigtail and
the incoming ground. For Interfaces using grounded metal
conduit, connect the ground pigtail to the metal back box ground
location.

c.

Install the ESD ground wire pigtail FASTON connector to the
mating receptacle on the Interface electronics.

3.

Terminate EchoConnect wires. EchoConnect is topology free, you may
install the wires in any combination of bus, star, loop, or home-run.

a.

Strip 7/16” (11 mm) from the ends of each EchoConnect power
pigtail wire (black and white wire pair), provided in the
termination kit, and the installed control wires.

b.

Use the WAGO connectors provided to connect the EchoConnect
pigtail wires and the installed Belden 8471 control wires. One
WAGO should be used for the white wire pair (data +) and one
for the black wire pair (data -). Open the terminal levers on the
WAGO connector and insert the installed Belden 8471 wire and
the lead from the power pigtail into the terminals then close the
levers.

c.

Install the two pin connector from the EchoConnect pigtail to the
mating receptacle on the station electronics.

4.

Terminate power supply wiring (24 VDC Auxiliary) wiring. 

a.

Strip 7/16” (11 mm) from the ends of each Auxiliary power
pigtail wire (black and red wire pair), provided in the termination
kit, and the installed power wires.

b.

Use the WAGO connectors provided to connect the Auxiliary
pigtail wires and the power wires. One WAGO should be used
for the red wire pair (p) and one for the black wire pair
(negative -). Open the terminal levers on the WAGO connector
and insert the installed wire and the lead from the power pigtail
into the terminals then close the levers.

c.

Install the two pin connector from the EchoConnect pigtail to the
mating receptacle on the station electronics.

ElahoAccess Interface Installation Guide

Page 4 of 8

Echoflex Solutions, Inc.

Summary of Contents for ElahoAccess Interface

Page 1: ...and devices Prepare for installation wall plate alignment bracket interface Included in shipment The ElahoAccess Interface ships with interface assembly decorator style wall plate 24 VDC power pigtail...

Page 2: ...t uses one pair of wires data and data Echoflex recommends using Belden 8471 or approved equal Class 2 wire The total combined length of an EchoConnect wire run using Belden 8471 or equal may not exce...

Page 3: ...ll national and local codes for electrical equipment Note NEC Class 2 product to be wired in accordance to NEC Article 725 and local jurisdiction requirements Install the back box plumb and square for...

Page 4: ...res and the installed Belden 8471 control wires One WAGO should be used for the white wire pair data and one for the black wire pair data Open the terminal levers on the WAGO connector and insert the...

Page 5: ...d when installing the Interface in a surface mounted box 1 Insert the Interface electronics and wiring into the back box To install multiple Elaho products multi gang insert the Interface electronics...

Page 6: ...ate is secured to the Interface with magnets that are assembled to the wall plate 1 Align the top of the wall plate to the Interface and angle the bottom approximately 20 degrees 2 Hook the top of the...

Page 7: ...tes uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee t...

Page 8: ...Echoflex Installation Guide ElahoAccess Interface ElahoAccess Interface Installation Guide Page 8 of 8 Echoflex Solutions Inc...

Reviews: