When using Category 5 (or equivalent) cable on the
EchoConnect communication bus, please note the following:
•
Cat5 wiring must be terminated using EchoConnect Cat5
Termination Kits and must be installed using a bus topology.
Refer to the installation guide that is provided with the Cat5
Termination Kit (8186A1207) for information to terminate
Cat5 wiring.
•
Not all topologies are supported using Cat5; careful planning
is required to ensure the proper termination kits are available
and the wire is pulled appropriately.
4. Terminate 24 VDC Aux Power wiring.
a. Strip 11 mm (0.4 in) from the ends of each Auxiliary Power pigtail
wire (black and red wire pair) provided in the termination supplies
and the installed power wires.
b. Use the WAGO connectors provided to connect the Auxiliary
pigtail wires and the power wires. One WAGO should be used for
the red wire pair (V+) and one for the black wire pair (V-). Open
the terminal levers on the WAGO connector and insert the
installed wire and the lead from the power pigtail into the
terminals, and then close the levers.
c. Install the two-pin connector from the Auxiliary Power pigtail to
the mating receptacle on the station electronics.
Install the Interface
Receptacle spacers are provided
to help align the Interface and
cover flush against the wall in
flush mount application. The
spacers are not required when
installing the Interface in a
surface mounted box.
1. Insert the Interface electronics and wiring into the back box. To install
multiple stations (multi-gang), insert each station electronics into the
back box from the right to the left side for the best alignment and fit.
The alignment bracket will slightly overlap the station to the right
when properly installed.
Access Interface
Page 4 of 8
Echoflex