background image

Echoflex Installation Guide

Access Interface

Note:

When using Category 5 (or equivalent) cable on the

EchoConnect communication bus, please note the following:

Cat5 wiring must be terminated using EchoConnect Cat5
Termination Kits and must be installed using a bus topology.
Refer to the installation guide that is provided with the Cat5
Termination Kit (8186A1207) for information to terminate
Cat5 wiring.

Not all topologies are supported using Cat5; careful planning
is required to ensure the proper termination kits are available
and the wire is pulled appropriately.

4. Terminate 24 VDC Aux Power wiring. 

a. Strip 11 mm (0.4 in) from the ends of each Auxiliary Power pigtail

wire (black and red wire pair) provided in the termination supplies
and the installed power wires.

b. Use the WAGO connectors provided to connect the Auxiliary

pigtail wires and the power wires. One WAGO should be used for
the red wire pair (V+) and one for the black wire pair (V-). Open
the terminal levers on the WAGO connector and insert the
installed wire and the lead from the power pigtail into the
terminals, and then close the levers.

c. Install the two-pin connector from the Auxiliary Power pigtail to

the mating receptacle on the station electronics.

Install the Interface

Receptacle spacers are provided
to help align the Interface and
cover flush against the wall in
flush mount application. The
spacers are not required when
installing the Interface in a
surface mounted box.

1. Insert the Interface electronics and wiring into the back box. To install

multiple stations (multi-gang), insert each station electronics into the
back box from the right to the left side for the best alignment and fit.
The alignment bracket will slightly overlap the station to the right
when properly installed.

Access Interface

Page 4 of 8

Echoflex

Summary of Contents for ElahoAccess

Page 1: ...figure and control your Elaho Presets Spaces Zones and devices Specification Installation Environment For indoor commercial controls use only Echoflex recommends paying special attention to the instal...

Page 2: ...25 4 cm 10 in of wiring in the back box for connection and to allow slack for future service needs Note Echoflex requires that all stations and devices be grounded for ESD protection Pull an additiona...

Page 3: ...he mating receptacle on the Interface electronics 3 Terminate EchoConnect wires EchoConnect is topology free you may install the wires in any combination of bus star loop or home run a Strip 11 mm 0 4...

Page 4: ...ed to connect the Auxiliary pigtail wires and the power wires One WAGO should be used for the red wire pair V and one for the black wire pair V Open the terminal levers on the WAGO connector and inser...

Page 5: ...ng the mounting screws provided If using spacers insert the screws through the spacers as well Interface LEDs Power The top blue LED lights when the device has power Bluetooth The bottom yellow LED li...

Page 6: ...cure Note If you are installing a multi gang wall plate and the stations are misaligned in the mounting box the wall play will not attach properly Loosen the screws that secure the station to the back...

Page 7: ...e of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that...

Page 8: ...own expense This device contains a wireless module with the following identification numbers FCC ID T9JRN4020 ISED Compliance This device contains a license exempt transmitter receiver that complies...

Reviews: