Installation
Prepare
To ensure optimal function, consider the installation environment and the
following guidelines:
• For indoor use only. Operating temperature 0°C–40°C (32°F–104°F),
5% to 95% relative humidity (non-condensing).
• High density construction materials and large metal appliances or
fixtures in the space may disrupt wireless reception.
• Install the WTC within range of linked lighting controllers, 24 m (80 ft)
unobstructed view. Consider adding a repeater to extend the wireless
signal, if required.
• External antenna options include extension cables and a magnet-mount
antenna for installation locations with poor wireless reception.
• Can be surface-mounted or flush-mounted in an industry standard
two-gang electrical box (not provided). The box must be installed plumb
and square. Ensure it is clean and free of obstructions to accommodate
the cable if using an external antenna.
• Provide a 24 V power supply connection to the target two-gang
electrical box.
• Pull the plastic tab to activate the installed CR2032 battery. The battery
is not required to run the WTC, it is only used to maintain the time in
case of a power outage.
Note:
Installation must follow all national and local codes for
electrical equipment.
Note:
An External Antenna Extension Kit is sold separately
through Echoflex, part number 8186K1001. Contact
Echoflex for more information.