background image

 

 

Echola Systems L.L.C 
1161 Ringwood Ct, Ste 100 
San Jose, CA-95131 
Phone: 408 321 9663 

http://www.echola.com/power

 

 

SPDU-116M Specification 

 

Input  

Acceptable Input voltage range  

100-120V AC 

Input plug type  

NEMA L5-30P  

 

Maximum Input Current 

30A (24A Derated) 

Input Current Monitoring Accuracy 

±5% 

Input Frequency 

50/60 Hz 

Cord Length 

8 feet 

Output 

 

Output voltage  

Same as Input 

Output receptacle type  

NEMA 5-20R 

 

Maximum Output current/outlet 

16A (Aggregate current of all outlets can't exceed Max. 
Input current) 

Number of Outlets 

16 

Outlet Current Monitoring Accuracy 

±10% 

Interfaces 

 

Network Interface 

RJ45, 10Base-T Ethernet 

Front Panel display 

2x16 Color character LCD with LED backlight 

Environmental 

 

Operating Environment  

32-113° F 

Operating Relative Humidity 

0-95% 

Operating Elevation 

0-10000 feet 

Physical 

 

Net weight  

~15 lbs 

Maximum height 

3.5 inches (2U) 

Maximum width 

17.5 inches 

Maximum depth 

8 inches 

Color 

Olive Green front panel, Grey chassis 

 

 

 

Summary of Contents for SPDU-108M

Page 1: ...ny unprotected power source such as a wall outlet Always connect to an appropriately rated branch circuit s outlet which provides short circuit protection using standard Circuit Breakers or Fuses Always maintain reliable earthing of the PDU Do not connect the PDU to an ungrounded outlet or adapters or extension cords that doesn t have ground connection The power requirement of each equipment conne...

Page 2: ... www echola com power Installing in a Rack The PDU can be installed in a standard 19 rack or enclosure It can be mounted horizontally at front of the rack or vertically at the back as shown below Rack Horizontal Installation Vertical Installation at the back of the Rack Outlet 1 Outlet 8 ...

Page 3: ...as Input Output receptacle type NEMA 5 20R Maximum Output current outlet 16A Aggregate current of all outlets can t exceed Max Input current Number of Outlets 8 Outlet Current Monitoring Accuracy 10 Interfaces Network Interface RJ45 10Base T Ethernet Front Panel display 2x16 Color character LCD with LED backlight Environmental Operating Environment 32 113 F Operating Relative Humidity 0 95 Operati...

Page 4: ...Output receptacle type NEMA 5 20R Maximum Output current outlet 16A Aggregate current of all outlets can t exceed Max Input current Number of Outlets 16 Outlet Current Monitoring Accuracy 10 Interfaces Network Interface RJ45 10Base T Ethernet Front Panel display 2x16 Color character LCD with LED backlight Environmental Operating Environment 32 113 F Operating Relative Humidity 0 95 Operating Eleva...

Page 5: ...receptacle type IEC 320 C13 7 IEC 320 C19 1 Maximum Output current outlet 16A Aggregate current of all outlets can t exceed Max Input current Number of Outlets 8 Outlet Current Monitoring Accuracy 10 Interfaces Network Interface RJ45 10Base T Ethernet Front Panel display 2x16 Color character LCD with LED backlight Environmental Operating Environment 32 113 F Operating Relative Humidity 0 95 Operat...

Page 6: ...receptacle type IEC 320 C13 14 IEC 320 C19 2 Maximum Output current outlet 16A Aggregate current of all outlets can t exceed Max Input current Number of Outlets 16 Outlet Current Monitoring Accuracy 10 Interfaces Network Interface RJ45 10Base T Ethernet Front Panel display 2x16 Color character LCD with LED backlight Environmental Operating Environment 32 113 F Operating Relative Humidity 0 95 Oper...

Page 7: ...net Protcol Properties of the ethernet interface Now launch the internet browser and type http echolasys in the address bar and press Enter key Now you will be prompted with a PDU s login dialog If this is first time then use default username and password After login you will see the main menu page of the PDU Now click on the Setup tab of the menu to bring the Network Config menu From here you can...

Page 8: ...fferent user who can access to main Control Monitor page but is not allowed to access Setup page This user is by default called guest but name can be changed using Setup User tab and default password is guest as well If the authentication fails Authentication Required message will be displayed The authentication can optionally be disabled for Control Monitor web page the home page on the main menu...

Page 9: ...U through user friendly web interface The web interface uses AJAX for providing near real time update on current consumption for each outlets total current Temperature and outlet statuses To access GUI from any smart phone mobile devices just use letter m after the ipaddress or the hostname like http 192 168 2 21 m For more details on web interface please refer to User s Manual at http www echola ...

Page 10: ... perl Command Syntax perl xmlget pl http ipaddress use LWP UserAgent use XML Simple IPADDR shift create objects xml new XML Simple ua LWP UserAgent new send request for api xml REQUEST IPADDR api xml req HTTP Request new GET REQUEST req header Cookie test quest res ua request req data xml XMLin res content print them print Outlet1 Power data pow1 print Outlet2 Power data pow2 print Outlet3 Power d...

Page 11: ...f java ver 5 or early 6 versions doesn t work well with the AJAX calls that we use for real time updates You can check whether you have latest java by clicking on following link http java com en download testjava jsp and do an update to avoid this intermittent problem Also check for any malware anti virus firewall software which might block the http connection to PDU We don t support router behind...

Reviews: