background image

20 

FLS 2D Instruction Manual

 

 

Some Common Faults 

 

Display doesn’t switch on (no display)

 

· 

Battery not connected 

· 

Battery voltage too low 

 

No display once switched on:- 
 

· 

LCD Faulty 

· 

Eyes shut 

 
No seabed visible and transmitter box LED is flashing:- 
 

· 

Transducer not connected (or not connected properly) - use Test Mode 

· 

Incorrect range selected (try using the ‘Auto’ setting!) 

 

Poor seabed picture or excessive noise:- 

 

· 

Suitable range not selected (try to fill screen with seabed) 

· 

Poor connection of transducer 

· 

Battery voltage low - use Test Mode to check Tx voltage 

· 

Transducer mounted at an angle 

· 

Turbulence at transducer location 

· 

Interference from other 200KHz sounders  (same boat or other boats) 

· 

Turbulence/wake from other boats 

· 

Polluted water or Plankton bloom (usually early summer) 

· 

Dirty transducer/covered with barnacles 

· 

Choppy sea state - can cause surface noise 

FLS 2D - Fault Finding 

FLS 2D Instruction Manual

 

 

FLS 2D Operating Instructions  

Keypad Operation - Overview 

 

Power Key: 

Switches the unit on and off. 

 

 
Menu Key:
 

Selects the menu which allows the user to modify the unit settings. See 

the section 

Changing the Unit Settings

 for more information on the menu. 

 

Up/Down  Keys:

    (Soft  key1/soft  key4)When  in  FLS  Mode  (sonar  data  displayed), 

changes the sonar range up or down accordingly. When in the menu, the up and down 
arrows  change  the  selected  option.  See  the  section 

Changing  the  Unit  Settings

  for 

more information on the menu. 
 

Mode  Key:  (soft  key  3) 

  When  in  the  menu,  the  mode  key  returns  the  user  to  the 

current mode.  
 

Page Key: (soft key 4) 

 

 

Operating Modes

 

 

FLS Mode 

FLS  Mode  is  the  sonar  operating mode  that  displays  the  sonar  image  of  the  seabed 
ahead and below the transducer. There are eight forward range settings  (20m, 40m, 
60m,  80m,  100m, 150m, 200m  and  Auto)  that  are  selectable  with the  up and down 
arrow  keys.  When  the  upper  range  is  reached  with  the  up  arrow  (200m),  a  further 
press puts the unit onto the ‘Auto’ range. Similarly, when the lower range is reached 
with   the  down  arrow,  a  further  press  puts  the unit  onto  the  Auto  range.  A  press  of 
either  arrow  key  while  Auto  is  on  will  switch  the  Auto  off  and  the  user  will  retain 
manual control of the range.  
 
When returning to manual range, the range selected will be the last range selected by 
the Auto function until the user presses an arrow key to change range. 

Summary of Contents for FLS 2D

Page 1: ...RINE ELECTRONICS LTD 1 Endeavour Park Crow Arch Lane Ringwood Hampshire United Kingdom BH24 1SF Telephone 01425 476211 2 Fax 01425 474300 E Mail info echopilot com Webpage www echopilot com Colour Forward Looking Sonar FLS 2D Instruction Book ...

Page 2: ...formance pleasure and safety from your equipment so please take the time to read the instructions Please observe the following warnings Please do not cut the transducer cables they are fine multi core cable matched to the transducer Please do not remove the transducer plug from its cable if a hole is too small make the hole bigger Any join in the cable will reduce sensitivity performance Disclaime...

Page 3: ...hts reserved Protected by USA Patent 5530680 and European UK Patent 0624253 Author Chris Phillips Chief Dogs Body Last Updated 22 05 2012 For up to date information and advice please telephone browse our Website or send us an E Mail e mail info echopilot com website www echopilot com 3 FLS 2D Instruction Manual Operating Instructions 4 Switching on 4 Keypad Operation Overview 5 Operating Modes 5 C...

Page 4: ...osen for the current depth Pressing the up or down arrows will turn off auto mode and the user will now have control of the range with the up and down buttons Up is soft key one down is soft key 4 as shown on the LCD 21 FLS 2D Instruction Manual Specification FLS Platinum Voltage 12v or 24v DC Current Consumption Display 380mA with max brightnes 150 mA min Operating frequency 200 kHz LCD type Tran...

Page 5: ...dify the unit settings See the section Changing the Unit Settings for more information on the menu Up Down Keys Soft key1 soft key4 When in FLS Mode sonar data displayed changes the sonar range up or down accordingly When in the menu the up and down arrows change the selected option See the section Changing the Unit Settings for more information on the menu Mode Key soft key 3 When in the menu the...

Page 6: ...been selected History Display The FLS 2D displays a 15 second history to the left of the vertical line 0m line on the sonar display The history plot is based on the digital depth readout and gives the user a little more information about the shape of the seabed behind the vessel As the history plot is the last 15 seconds of seabed the area of seabed covered will depend on the speed of the vessel F...

Page 7: ...natively the user can return to the sonar display by pressing the mode key Shallow Alarm The Shallow Alarm can be set to Off or 1m to 20m When a certain number of echoes occur above this setting an alarm will sound 1 second on 1 second off The alarm setting is retained after power down The shallow alarm is provided as a guide to warn the user that echoes are appearing above the set level It should...

Page 8: ...at Length Allows the user to set the displayed boat length to match their own boat up to a maximum of 20m Boat Type 3 boat types are available to the user 2 motor boats and 1 sailing boat Bow Offset 17 FLS 2D Instruction Manual FLS 2D Installation Instructions Fitting the display The FLS 2D is designed to be flush mounted on an instrument panel or bulkhead or alternatively bracket mounted The brac...

Page 9: ... CUT THE TRANSDUCER CABLE 9 FLS 2D Instruction Manual FLS 2D Operating Instructions This is the distance from the boat s bow to the transducer position and allows the user to obtain a more realistic picture of the seabed with respect to the vessel Language Allows one of the currently available languages to be selected for unit operation Depth Units Units can be set to Metres or Feet Depth Offset T...

Page 10: ...en seriously If in doubt use an experienced shipwright For the standard plastic skin fitting cut a 45 mm 1 3 4 diameter hole For the Professional bronze skin fitting cut a hole 60 mm 2 1 2 in diameter Fit the skin fitting with reinforcing pads if needed or wedges if required to ensure the transducer is as near to vertical as possible fore aft AND port starboard Use plenty of underwater sealant but...

Page 11: ...nnot see around corners so stand under the boat with your head near the proposed position You must be able to see from your toes up to above the horizontal ahead If the boat has a full or deep forefoot obstructing the view a more forward position maybe called for 11 FLS 2D Instruction Manual How FLS Technology Works Sonar Beam The EchoPilot FLS is a unique and patented invention It can see through...

Page 12: ...ce and air bubbles will limit the performance of the FLS system or any depth system for that matter However if a place can be found on the hull where there is a clear flow of water then good results can be obtained even at speed 13 FLS 2D Instruction Manual Transducer Installation The choice of transducer position will have a major effect on final performance so please consider carefully all facto...

Reviews: