960E
Installation Manual
ECI Telecom Ltd. Proprietary
48
B.4.7.
Ethernet 8 and 9
Ethernet 8 and 9 are located on the CCP of the 960E and are RJ-45 females. The pin-
out is described in the following table.
Table 5: Ethernet 8 and 9 RJ-45 Pin out
RJ-45
Connector
Pin
Signal
1 ETHBTXH
2 ETHBTXL
3 ETHBRXH
4 B_ETHTXH
5 B_ETHTXL
6 ETHBRXL
7 B_ETHRXH
8 B_ETHRXL
B.4.8.
Fiber Optic SFP Transceiver Specification and Types
The SFP transceiver is installed in the SFP cage.
The SFP types applied to the 960E are listed below.
Table 6: SFP Types
Interface
Optical
Receiver
Sensitivity
Wavelength
Connector
Type
Transmission
Distance Vs. Cable
Specifications
1000BASE-SX
-17dBm
850nm
LC
550m / 50um MMF
1000BASE-LX-I
-22dBm
1310nm
LC
10Km / 10um MMF
1000BASE-LX-L
-22dBm
1310nm
LC
20Km / 10um MMF
1000BASE-LX-E
-22dBm
1310nm
LC
40Km / 10um MMF
1000BASE-ZX
-24dBm
1550nm
LC
80Km / 10um MMF
1000BASE-T
N/A
N/A
RJ-45
100m / Copper Cat. 5
Note
: The operating distance varies for each system design. Therefore, the results are
not official and should be considered as a reference only.
Note
: The 960E is not supplied with an SFP Transceiver.