10
7.2.3. Remote port
(Only applies to the eMOTUS5PB model)
REMOTE
port: the RJ-45 REMOTE type connector makes it possible to connect from a
type WPaVOL wall control panel (control 0-10 VDC) for adjusting the general output
volume. The connection is made by a standard CAT5 cable between the WPaVOL wall
panel and the REMOTE connector on the MASTER unit.
As there is an eMOTUS5PB kit along with a type WPa control and other types of control
(rotating control on the rear panel, remote control or control via remote port), at all
times, the latest adjustments made using one or another method will prevail. For
instance, if the volume is adjusted using a WPaVOL wall panel connected to the
REMOTE port, and then said parameters are altered using the control on the rear panel,
the latest adjustment will prevail. In this case, when the position of the wall panel is
altered again, the eMOTUS5PB kit will retake the values that this indicates, and so on.
Note:
the green LED light will keep on whenever the unit is on. It will blink on and off
when there is activity in the remote controls (remote control or 0-10VDC port).