5.6. Programming and control Ethernet port
The RJ45 connector labeled ETHERNET allows the connection of the equipment to an
Ethernet local network (LAN), being compatible with the following purposes:
Management from the EclerNet Manager application, by direct connection (CAT5
cable or higher) of a computer with a MIMO4040DN unit or using an Ethernet
network as a link between both. Refer to the EclerNet Manager Application manual
for more information.
Connection to third party control equipment. (Crestron, AMX, Extron, Medialon, etc.
are registered brands from their respective owners). Protocol used: Ecler TP-NET.
Refer to the TP-NET protocol manual for more information.
UCP: EclerNet project remote control service using customisable graphical control
panels. MIMO4040DN can act as a server for these panels, included in an EclerNet
project, and also be remotely controlled by UCP panel client devices
(WPNETTOUCH, Android® or iOS® mobile devices, Windows® devices, etc.).
5.7. Control remote RS-232 port
The RS-232 port with DB9 connector built into the rear panel allows an external device
to communicate with a MIMO4040DN unit via serial connection. This connection will
use the syntax of the TP-NET protocol so that the external device can obtain the value
of some of the parameters of the MIMO4040DN unit (by means of "GET" commands)
and/or modify these values ("SET" commands). Refer to the TP-NET protocol manual for
more information.
The serial connection must comply with the following characteristics:
Baud rate: 115200 (fixed, no auto negotiation)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None