background image

 

 

8.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or 

other apparatus (including amplifiers) that produce heat.  

9.

 

Do  not  defeat  the  safety  purpose  of  the  polarized  or  grounding  type  plug.  A 
polarized plug has two blades with one wider than the other. A grounding type 

plug has two blades and a third grounding prong. The wide blade and the third 

prong  are  provided  for  your  safety.  If  the  provided  plug  does  not  fit  into  your 

outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect  the  power  cord  from  being  walked  on  or  pinched  particularly  at  the 

plugs,  convenience  receptacles,  and  at  the  point  where  they  exit  from  the 

apparatus.  

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Unplug the apparatus during lightening sorts or when unused for long periods of 

time. 

13.

 

Refer  all  servicing  to  qualified  personnel.  Servicing  is  required  when  the 

apparatus has been damaged in any way, such as power supply cord or plug is 

damaged, liquid has been spilled or objects have fallen into the apparatus, the 

apparatus has been exposed to rain or moisture, does not operate normally, or 

has been dropped. 

14.

 

Disconnecting  from  mains:  switching  off  the  POWER  switch  all  the  functions 

and light indicators of the amplifier will be stopped, but fully disconnecting the 

device  from  mains  is  done  unplugging  the  power  cord  from  the  mains  input 

socket. For this reason, it always shall remain readily operable. 

15.

 

Equipment is connected to a socket-outlet with earthing connection by means of 

a power cord.  

16.

 

The marking information is located at the bottom of the apparatus. 

17.

 

The apparatus shall not be exposed to dripping or splashing and that no objects 

filled with liquids, such as vases, shall be placed on apparatus.  

 

WARNING

:

 

This  product  must  not be  discarded,  under  any  circumstance,  as 

unsorted  urban  waste.  Take  it  to  the  nearest  electrical  and  electronic  waste 
treatment centre. 

 

NEEC  AUDIO  BARCELONA,  S.L.

  accepts  no  liability  for  any  damage  that  may  be 

caused to people, animal or objects due to failure to comply with the warnings above.  

 

 

Summary of Contents for MIMO4040DN

Page 1: ...v 20190416 MIMO4040DN DIGITAL MATRIX Digital Matrix with Dante Interface USER MANUAL ...

Page 2: ... analog audio inputs 8 5 4 Balanced analog audio outputs 8 5 5 Digital audio inputs and outputs over IP Dante 9 5 6 Programming and control Ethernet port 11 5 7 Control remote RS 232 port 11 5 8 Remote control GPI ports 12 5 9 Remote control GPO ports 13 6 OBSERVATIONS 13 7 1 Ground loops 13 7 2 Background noise 13 7 PACKAGE CONTENTS 14 8 FUNCTION LIST 14 9 FUNCTION DIAGRAM 15 10 BLOCKS DIAGRAM 16...

Page 3: ...rked with symbol of may be of sufficient magnitude to constitute a risk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outl...

Page 4: ... any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 14 Disconnecting from mains switching off the POWER switch all the functions and light indicators of the amplifier will be stopped but fully disconnecting the device from mains is don...

Page 5: ...wnload at www ecler com It has 8 analog audio inputs and 8 analog audio outputs 32 digital audio inputs Dante and 32 digital audio outputs Dante converting it into a native 40x40 matrix with real routing of any input to any output 4 1 Main features 8 balanced MIC LINE analog audio inputs 42VDC phantom power independent per input channel Euroblock connectors 8 balanced analog audio outputs Eurobloc...

Page 6: ...ect Configuration memory management presets Events scheduled on a calendar basis Broad DSP processing configurable Exemples o Matrix router mixer from any input to any output analog and or digital Dante with adjustable crosspoint level independent mixes of different inputs for each output o Treatment of channels in mono or stereo mode o Level mute vumeters and phase adjustment in inputs and output...

Page 7: ...eans of doors it is highly recommendable to equip them with forced upward ventilation installing fans at their lower and upper ends This upward flow of ventilation will favor the dissipation of the heat generated in its interior 5 2 Mains connection and power on MIMO4040DN operates on alternating voltages from 90 to 264V and 47 to 63 Hz This device is equipped with an oversized power supply capabl...

Page 8: ... of the connection is as follows Live or direct signal Terminal Cold or inverted signal Terminal Ground Terminal For UNbalanced connections short circuit the terminal to earth 5 4 Balanced analog audio outputs The rear panel of the MIMO4040DN has 8 analog signal outputs OUT 1 to 8 and 2 additional MONITOR monitoring outputs balanced and with line level The signal output connectors are Euroblock ty...

Page 9: ...nte labeled as primary PRIMARY and secondary SECONDARY MIMO4040DN can work with these ports in two possible modes Redundant Mode there are two simultaneous network connections each with its own IP address both different so that the information Ethernet packets Dante are transmitted via both connections Each port primary and secondary must be connected to a different physical Ethernet local network...

Page 10: ... connects to a network with a 1 Gbps link the secondary port must also connect at 1 Gbps Switched mode in this mode only a single network connection is actually enabled and therefore only one IP address exists with the primary and secondary ports behaving as ports of a network switch integrated within MIMO4040DN to which devices forming part of the system s Dante network or Ethernet switches formi...

Page 11: ...te control service using customisable graphical control panels MIMO4040DN can act as a server for these panels included in an EclerNet project and also be remotely controlled by UCP panel client devices WPNETTOUCH Android or iOS mobile devices Windows devices etc 5 7 Control remote RS 232 port The RS 232 port with DB9 connector built into the rear panel allows an external device to communicate wit...

Page 12: ...eries from Ecler Activation deactivation of a MUTE or SOLO by means of a push button or contact closure Retrieval of a preset by means of a pushbutton or contact closure The GPI connectors are Euroblock type The assignment of the connection is as follows Positive 10 VDC Terminal Variable voltage 0 10 VDC Terminal Ground Terminal Some connection examples The connection cables can be up to 500 meter...

Page 13: ...hassis must never be connected to each other This way we avoid the formation of ground loops 7 2 Background noise MIMO4040DN has been designed to obtain the lowest possible background noise Regardless of the electronic design the background noise will depend directly on the correct use and installation of the unit It is not the same for example to have the GAIN control of a channel at 2 and the VO...

Page 14: ...6 Digital audio traffic light Dante DANTE 7 Start up indicator light POWER 8 IEC type connector for external AC power cable 9 Fuse holder 10 Unit Power On Switch 11 Euroblock DC voltage control terminals GPI 12 Euroblock relay output terminals GPO 13 Ports Dante primary and secondary RJ 45 connector 14 Ethernet control port RJ 45 connector 15 DB9 connector for remote control via TP NET protocol RS...

Page 15: ...15 9 FUNCTION DIAGRAM ...

Page 16: ...16 10 BLOCKS DIAGRAM ...

Page 17: ... in 0 5dB steps Input impedance Balanced 4k Phantom power 42VDC 5mA max software switched Headphones 200mW 200 Frequency response 3dB 5Hz to 24kHz Flatness better than 0 1dB THD Noise 1kHz 0dBV input line 0 004 THD Noise 1kHz 40dBV input mic 0 008 Output Noise floor FFT 20Hz 20kHz better than 115dB Interchannel crosstalk 20Hz 20kHz better than 90dB 100dB typ Channel Leakage 20Hz 20kHz better than ...

Page 18: ...l in 12 18 24 dB oct Linkwitz Riley in 12 24 dB oct Input noise gate x40 Bypass On Off Threshold from 80 dBV to 18 dBV Depth 0 dB to 80 dB Attack time from 0 1 ms to 500 ms Hold time from 10 ms to 3000 ms Release time from 10 ms to 1000 ms Input compressor limiter x40 Bypass On Off Threshold from 36 dBV to 18 dBV Knee hard soft Ratio inf 1 limiter Attack time from 0 1 ms to 500 ms Release time fro...

Page 19: ...None Melody 1 Melody 2 Chime Volume from 12dB to 0dB Mechanical Dimensions 482 6 x 44 0 x 266 5mm 19 0 x 1 7 x 10 5 Weight 3 25kg 7 17 lb Power supply Mains 90 264VCA 47 63Hz Power consumption 30VA Miscellaneous Management Connectivity Ethernet Base Tx 10 100Mb 1GB Auto X Over CAT5e or better GPI 8 from 0 to 12VDC or TTL level GPO 8 3 poles isolated relay 1A 48VDC max Aux Power Supply for Remotes ...

Page 20: ...e to production tolerances NEEC AUDIO BARCELONA S L reserves the right to make changes or improvements in design or manufacture that may affect these product specifications Motors 166 168 08038 Barcelona España 34 932238403 information ecler com www ecler com ...