7
5.
INSTALLATION
5.1. Location, assembly and ventilation
MIMO4040DN has been specially designed to be placed in 19" rack structure,
occupying one unit.
It is very important that, as a heat generating element, MIMO4040DN is not completely
enclosed or exposed to extreme temperatures. Fresh air should be allowed to pass
through the ventilation holes in the chassis, leaving at least one free rack unit between
each piece of equipment and those installed above and below it in the rack frame.
If the installation consists of several amplifiers in the same rack or is carried out inside
cabinets closed by means of doors, it is highly recommendable to equip them with
forced upward ventilation, installing fans at their lower and upper ends. This upward
flow of ventilation will favor the dissipation of the heat generated in its interior.
5.2. Mains connection and power on
MIMO4040DN operates on alternating voltages from 90 to 264V and 47 to 63 Hz. This
device is equipped with an oversized power supply capable of adapting without any
type of adjustment to the mains voltage of any country in the world.
On the rear panel, next to the IEC power connector, there is an on/off switch for the unit.
On the front panel there is an LED indicator that illuminates when the unit is in
operation.
Do not allow the network cable to run parallel to the shielded cables carrying the audio
signal, as this may cause humming.