8
5.4. Audio Output Connections
The rear panel of a MIMO SG offers 8 (MIMO88SG) or 12 (MIMO1212SG) analogue signal
outputs "OUT", all balanced and accepting line level
signals.
Signal output connectors are 3 position screw terminal
block. The wiring is:
Hot or direct signal
>
Te
Cold or inverted signal
>
Terminal -
Ground
>
Terminal
⊥
For UNBALANCED connections, leave the
–
terminal unconnected.
5.5. ETHERNET port for programming and control
An RJ45 type connector allows connecting the equipment to an Ethernet network:
•
Management from EclerNet Manager application. Please refer to the EclerNet
Manager Software manual for more information.
•
Possibility of direct connection (point to point) between a computer and a MIMO SG
unit.
•
Connection to third party other devices. (Crestron, AMX, Vity, Medialon, etc.
Registered trademarks of their manufacturers). Protocol used: Ecler TP-NET. See
the TP-NET protocol manual for more information.
•
Connection to WPmSCREEN units (remote control of an entire network of EclerNet
devices through custom graphic panels).
5.6. REMOTE port for digital remote controls
The REMOTE port allows the connection of digital remote-control
devices, such as the WPTOUCH wall panel or the MPAGE16 paging
console. The REMOTE port is connected to the digital control bus the
remote devices are daisy-chained to, the last one being loaded with a
120
termination resistor between CAN HIGH and CAN LOW.
Refer to the remote device documentation (WPTOUCH, MPAGE16, etc) for more
information about your connection and controls.