9
Please refer to the EclerNet Manager Software manual for more information about
programming a MIMO SG to manage the remote devices that are connected to the
REMOTE port.
5.7. GPI Remote Control Ports
The rear panel of the MIMO SG offers 8 (MIMO88SG) or 12 (MIMO1212SG) GPI inputs
for 0-10 VDC continuous control voltage. Each of these inputs can be connected to an
external physical device (potentiometer, contact closure, continuously variable voltage 0-
10V DC, etc.) and assigned to a MIMO SG function, as for example:
•
Input, output channel or matrix crosspoint volume remote control by means of a
WPmVOL physical knob or an Ecler WPm Series’ WPVOL
-IR remote control
•
MUTE or SOLO activation/deactivation by means of a switch or contact closure
•
Recalling a
preset
with a push button or contact closure
GPI connectors are screw terminal blocks with three-contacts. The wiring is as follows:
Positive, + 10 VDC
>
Pin +
Variable voltage, 0-10 VDC
>
Pin
↑
Ground
>
Pin
⊥
WPaVOL connection to MIMO serial GPI ports
Jumpers position: ALOG / LIN
→
LIN position
+12 / +10
→
+12 position
WPaVOL RJ45 pin 6 (+12VDC/+10VDC)
WPaVOL RJ45 pin 2 (Remote ZONE.)
WPaVOL RJ45 pin 1, 3 or 7 (GND)