3.8. GPI Remote Control Ports
The rear panel of the MIMO88 offers 8 GPI inputs (16) for 0-10 VDC continuous control voltage. Each of
these inputs can be connected to an external physical device (potentiometer, contact closure, continuously variable
voltage 0-10V DC, etc.) and assigned to a MIMO88 function, as for example:
•
Input, output channel or matrix crosspoint volume remote control by means of a WPVOL physical
knob or an Ecler WP Series WPVOL-IR remote control
•
MUTE or SOLO activation/deactivation by means of a switch or contact closure
•
Recalling a
preset
with a push button or contact closure
GPI connectors are screw terminal blocks with three-contacts. The wiring is as follows:
Positive, + 10 VDC
>
Pin +
Variable voltage, 0-10 VDC
>
Pin
Ground
>
Pin
⊥
Examples of connection
Connecting cables can be up to 500 meters with a minimum section of 0.5 mm
2
.
Consult your ECLER dealer or www.ecler.com about the WP series remote control wall panels and other
accessories available for connection to the REMOTE/VCA port.
3.9. GPO Remote Control Ports
The rear panel of the MIMO88 offers 8 NO/NC (normally open/ normally closed) relay outputs (15). Each of
these outputs may be assigned to a MIMO88 function, such as a button of EclerNet Manager (MUTE key, SOLO
key, etc.). This makes it possible to interact with external devices such as projection screen motors or movable