4
1. IMPORTANT NOTE
Congratulations! You are the owner of a carefully designed and manufactured equipment. We thank you for
trusting on us and choosing our amplifier XPA.
In order to obtain maximum operativity and perfect functioning order, it is most important to carefully read all
considerations taken into account in this manual before connecting this amplifier.
We recommend our authorised Technical Services if any maintenance task should be needed so that
optimum operation shall be achieved.
1.1. Precautions
The XPA7000/5000/3000 amplifiers have a power consumption of 775, 675 and 575 VA (at 1/8 of
maximum power output, as specified by regulation EN 55103-1). We recommend a 2.5mm
2
(or bigger) wire cross-
section and a magnetothermic circuit breaker that can handle at least 10A@230VAC. (15A@230VAC for
XPA7000) (These values are for one amplifier).
The amplifier should have an earth connection in good conditions (earth resistance, Rg=30
Ω
or less). The
environment must be dry and dustless. Do not expose the unit to rain or water splashes, and do not place liquid
containers or incandescent objects like candles on top of the unit. Do not obstruct the ventilation shafts with any
kind of material. In case there is some type of intervention and/or connection-disconnection of the amplifier, it is most
important to previously disconnect the mains power supply.
Do not manipulate the output terminals to the loudspeakers when the amplifier is switched on, there are
voltages up to 400Vpp. The output cabling should be connected by a qualified technician. Otherwise only
use pre-made flexible cables. There are no user or serviceable parts inside the amplifier.
2. INTRODUCTION
High efficiency mosfet amplifier.
Ecler XPA Power amplifier series offers the renowned professional reliability of all Ecler amplifiers at an
affordable price. The line consists of three models with power outputs of 300, 500 and 700 W per channel at 4
Ω
. All
models employ mosfet amplification technology, are 2 rack units high and are based on a robust chassis with
aluminium front panel. Thanks to their oversized power supply, these amplifiers can operate comfortably with 4
Ω
and even 2
Ω
loads.
They feature balanced input connections via XLR3 and 1/4’’ Jacks. The outputs offer total versatility thanks
to secure connection posts with standardized separation and Speakon® sockets. An electronic limiting system for
avoiding signal overloads and a switchable subsonic filter are also on board.
2.1. Main features:
- Highly effective progressive cooling system. Air flow rises as a function of amplifier temperature. “Back to
Front” cooling system takes air from the rear and throws it out at the front panel.
- Easily accessible input attenuation controls on the front panel may be locked with Ecler exclusive system.
- Indicators for Signal Present (SP), Clipping (CLIP) and activation of protection circuits (PROT)
- Effective protection systems against short-circuit, excessive temperature due to accidental blocking of air
flow or other circumstances, DC at the output… to protect the amplifier and loudspeakers.
- Built-in, always active anticlip circuit
- Switchable subsonic filter, 30 Hz 18dB/oct slope
- Operating mode selector: STEREO, PARALLEL and BRIDGE
- Input sensitivity selector (0.775, 1, 1,4V)
- Balanced inputs via XLR3 and 6,35mm TRS Jack sockets
- Outputs on connection posts and Speakon® connectors
- Operation with 8, 4 and 2
Ω
or 4
Ω
in bridged mode.
- 2 years warranty