background image

 

18

SCAN NO 

001

SET LEFT LIMIT 

SET RIGHT LIMIT    

SCAN SPEED 

160 

RUN 

STOP 

BACK 

EXIT 

z

 

Set preset: 

Set preset 26 or 92 to set scan left limit. Set preset 27 or 93 to set scan right limit. Set 

preset 22 or 79 to begin record. Set preset 23 or 80 to stop record. 

 

4.4.4.2

 Pan 

 
 
 
 
 

Move the cursor to PAN button and then click confirm button to go to setup interface.  

z

  PAN SPEED: Set dome rotation speed. Please use the left/right button on the keyboard or in the speed 

dome terminal menu to set.    

z

  RUN: Move the cursor to call item and then click confirm button. The dome begins 360 degrees 

continuous rotation. 

z

  STOP: Highlight stop item and then click confirm button. The dome stops rotation. 

z

  BACK: Go back to previous menu.  

z

  EXIT: Log out system menu. 

 
4.4.4.3

 Scan 

 

 
 
 
 
 

 

Move the cursor to SCAN button and then click confirm button. 

z

 SCAN 

NO

Here is to set auto scan number. Please use the left/right button on the keyboard or in the 

speed dome terminal menu to set.    

z

  SET LEFT LIMIT

Here is to set camera left address. Click confirm button to save current setup. 

z

 SET 

RIGHT 

LIMIT

Here is to set camera right address. Click confirm button to save current setup. 

z

  SCAN SPEED: Please use the left/right button on the keyboard or in the speed dome terminal menu to 

set.     

z

  RUN: Please input auto scan number first, and then please move the cursor to RUN and click confirm 

button to activate auto scan function.  

z

  STOP: Here is to terminate auto scan function. 

z

  BACK: Go back to previous menu.  

z

  EXIT: Log out system menu. 

 

4.4.4.4

  Cruise (Touring) 

 
 
 

PAN SPEED    

160

RUN 

STOP 

BACK 

EXIT 

Summary of Contents for ECL-IPSP220I

Page 1: ...ECL IPSP220I User s Manual Version 1 3 0...

Page 2: ...2 7 Auto Pattern 1 1 2 8 Privacy Masking 1 1 2 9 Action on Alarm 2 1 2 10 Auto Flip 2 1 2 11 Self diagnosis 2 1 2 12 Day Night Mode B W Color Mode 2 1 2 13 Auto Focus 2 1 2 14 Backlight Compensation...

Page 3: ...t Setup 24 4 5 Dome Abnormal Phenomenon Operation 25 4 5 1 Restore to Factory Default Setup 25 4 5 2 PTZ Movement is not smooth 25 5 CABLE CONNECTION 26 5 1 Combination Cable Connection 26 5 2 System...

Page 4: ...eference tool for the operation of your system Here you can find information about this speed dome features and functions as well as a detailed menu tree Please keep it well for future reference Befor...

Page 5: ...the water and other liquid falling into the device This series product complies with the IP66 standard specified in the Degrees of Protection Provided by Enclosure z Please make sure the CCD CMOS com...

Page 6: ...v Before installation please open the package and check that all the components are included in the package Contact you local retailer ASAP if something is missing in your package...

Page 7: ...speeds in proportion to depth of zoom When zooms speed is increasing the camera moving speed becomes slow When zooms speed is decreasing the camera moving speed becomes fast 1 2 3 On screen Tips Here...

Page 8: ...to select day night mode This function needs the speed dome driver camera supported 1 2 13 Auto Focus Auto focus allows the lens to remain in focus during zoom in zoom out and motion functions to get...

Page 9: ...2 2 Operation Double click the ConfigTools exe icon you can see an interface is shown as in Figure 2 1 In the device list interface you can view device IP address port number subnet mask default gatew...

Page 10: ...lick the Login button to go to the login interface See Figure 2 4 In Figure 2 4 you can view device IP address user name password and port Please modify the corresponding information to login Please n...

Page 11: ...5 Figure 2 5 For detailed information and operation instruction of the quick configuration tool please refer to the Quick Configuration Tool User s Manual included in the resources CD...

Page 12: ...e corresponding gateway and subnet mask z Use order ping IP camera address to check connection is OK or not 3 2 Login and Logout Open IE and input IP camera address in the address bar For example if y...

Page 13: ...er name and password Default factory name is admin and password is admin Select the network connection type The login type includes TCP UDP Multicast Note For security reasons please modify your passw...

Page 14: ...8 Figure 3 4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction...

Page 15: ...TITILE DISPLAY OFF BACK EXIT DISPLAY SETTING SYSTEM INFORMATION CAMERA SETTING FUNCTION SETTING EXIT WB SETTING EXPOSURE SETTING DAY NIGHT SETTING PICTURE ADJUST FOCUS SETUP ZOOM SPEED 08 APERTURE 06...

Page 16: ...oftware Dome PTZ software version When you are using the control keyboard or the matrix host to control the device please make sure the control parameter of the keyboard or the matrix host is the same...

Page 17: ...RMATION Move the cursor to SITE INFORMATION and then click confirm button to go to the third submenu z SYSTEM TIME SETTING Move the cursor to SYSTEM TIME SETTING and then click confirm button to go to...

Page 18: ...nt coordinates or not Please use the left right button on the keyboard or in the speed dome terminal menu to set z TIME DISP Display dome system time or not Please use the left right button on the key...

Page 19: ...URE It is to adjust the lens to achieve clear video Please use the left right button on the keyboard or in the speed dome terminal menu to set z APERTURE CONTROL LEVEL System can auto reduce the apert...

Page 20: ...he keyboard or in the speed dome terminal menu to set z EXPOSURE COM Please use the left right button on the keyboard or in the speed dome terminal menu to set z SLOW AE In the strong light environmen...

Page 21: ...peed dome terminal menu to set z DAY TIME Current setup becomes valid when day night mode is Time Move the cursor to DAY TIME item and then click confirm button to go to setup Please user up down butt...

Page 22: ...the left right button to enable disable the digital zoom function z PICTURE FLIP There are two options on off Please use the left right button on the keyboard or in the speed dome terminal menu to se...

Page 23: ...camera System will automatically name a title for the camera z SETTING Please input preset number first and then select the monitor zone Please move the cursor to setting and click confirm button The...

Page 24: ...ion z BACK Go back to previous menu z EXIT Log out system menu 4 4 4 3 Scan Move the cursor to SCAN button and then click confirm button z SCAN NO Here is to set auto scan number Please use the left r...

Page 25: ...rm button to set the cruise Please use up down button to set preset number dwell time and speed Use the left right button to go to the next cruise Click confirm button you can exit the setup After you...

Page 26: ...utton System stops current pattern z BACK Go back to previous menu z EXIT Log out system menu Note z The dwell time between two orders should be less than one minute otherwise system will set to defau...

Page 27: ...click the confirm button you can set the task begin time end time action and etc WEEK Here you can set the week information Please use the left right button to set You can set for one day or you can...

Page 28: ...te the setup POWER UP It is to set the PTZ action when the speed dome boots up Click the confirm button to go to the next interface To set MENU PASSWORD It is to set the password to go to the PTZ menu...

Page 29: ...y to adjust privacy zone direction and size Fifthly move the cursor to SAVE and then click confirm button to exit z PRIVACY NO Here is to set privacy mask zones Please use the left right button on the...

Page 30: ...sor to the SAVE button and then click the confirm button to save current setup Click the BACK button to go to the previous menu BACK Go back to the previous menu EXIT Log out the system menu If you ha...

Page 31: ...ove cursor to FACTORY DEFAULT and click confirm button Dome will reboot and all the setups restore to factory default setup 4 5 2 PTZ Movement is not smooth From menu to SYSTEM INFORMATION move cursor...

Page 32: ...twork port Connect to network cable z Two alarm input channels It is to receive relay signal from the external alarm source You can go to dome menu to activate specified preset or patter z When the ac...

Page 33: ...Please refer to Figure 5 1 for system connection information Figure 5 1 5 2 2 Alarm Connection Please refer to Figure 5 2 for alarm connection information Figure 5 2 Network Output AC220V Input Transf...

Page 34: ...n the power board is on z Power supplying is low z Something wrong with power board z Use multimeter to check dome load z Please contact retailer to replace power board Power supplying is inadequate R...

Page 35: ...e point to the earth Open floor cable layout is forbidden z In area of strong thunderstorm hit or near high sensitive voltage such as near high voltage transformer substation you need to install addit...

Page 36: ...ndicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ T11363 2006 standard During the environme...

Page 37: ...ware here are subject to change without prior written notice All trademarks and registered trademarks are the properties of their respective owners If there is any uncertainty or controversy please re...

Reviews: