Eclipse AirHeat Burner, V2,  Design Guide 135, 6/16/2010

Safety

Important notices for safe operation of the burner system
will be found in this section. To avoid personal injury,
damage to property or the facility, the following warnings
must be observed. Read this entire manual before
attempting to start the system. If any part of the
information in this manual is not understood, contact
Eclipse before continuing.

Safety Warnings

Ŷ

  The burners covered by this guide are designed to

mix gas with air and burn the resulting mixture. All
gas burning devices are capable of producing fires
and explosions if improperly applied, installed,
adjusted, controlled or maintained.

Ŷ

  Do not bypass any safety feature; fire or explosion

could result.

Ŷ

  Never try to light a burner if it shows signs of

damage or malfunction.

Ŷ

  The burner and duct sections are likely to have

HOT surfaces. Always wear protective clothing
when approaching the burner.

Ŷ

  This manual provides information in the use of the

burner for its specific design purpose. Do not
deviate from any instructions or application limits
described herein without written advice from
Eclipse.

Capabilities

Only qualified personnel, with good mechanical aptitude
and experience with combustion equipment, should
adjust, maintain or troubleshoot any mechanical or
electrical part of this system.

Operator Training

The best safety precaution is an alert and trained
operator. Train new operators thoroughly and have them
demonstrate an adequate understanding of the
equipment and its operation. A regular retraining schedule
should be administered to ensure operators maintain a
high degree of proficiency.

Replacement Parts

Order replacement parts from Eclipse only. Any customer
supplied valves or switches should carry UL, FM, CSA,
CGA and/or CE approvals where applicable.

DANGER

WARNING

NOTICE

2

Summary of Contents for AirHeat AH series

Page 1: ...Eclipse AirHeat Burner AH Serie 135 Design Guide 6 16 2010 Version 2...

Page 2: ...It must be understood that Eclipse s liability for its product whether due to breach of warranty negligence strict liability or otherwise is limited to the furnishing of replacement parts and Eclipse...

Page 3: ...ty 5 Safety Warnings 5 Capabilities 5 Operator Training 5 Replacement Parts 5 3 System Design 6 Design 6 Step 1 Burner Option Selection 6 Step 2 Blower Option Selection 7 Step 3 Control Methodology 8...

Page 4: ...supplied with a variety of control motor and linkage options Ignition can be by direct spark or by spark ignited pilot Flame rod flame supervision can be from either or both ends Several air flow swi...

Page 5: ...and duct sections are likely to have HOT surfaces Always wear protective clothing when approaching the burner This manual provides information in the use of the burner for its specific design purpose...

Page 6: ...lt EFE 825 Eclipse Combustion Engineering Guide or contact Eclipse Combustion if you have special conditions or questions Burner Model Size Selection Consider the following when selecting the burner s...

Page 7: ...unt to the burner Burners can be ordered with control motor bracket and mounting hardware only Customer supplied control motors must conform to the these specifications rotation not to exceed 2 rpm mi...

Page 8: ...Control Methodology Input is normally controled by a motorized butterfly valve in the gas line to the burner A control signal is sent from a process temperature controller sold separately to the cont...

Page 9: ...ith the burner and includes an adjustable flow gas cock and pressure regulator It is not possible to use a continuous or intermittent pilot The pilot fuel flow should be interrupted after the trial ig...

Page 10: ...mplies with all local safety standards and codes set by the authorities within that jurisdiction Contact Eclipse for further information NOTE Eclipse supports NFPA regulations two gas shut off valves...

Page 11: ...mm inch in 3 94 x 10 2 MJ Nm BTU ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 001 From T...

Page 12: ...n both sides of the main gas shut off valve train 710 Solenoid Shut Off Valve Normally Closed Solenoid valves are used to automatically shut off the gas supply on a bypass gas system or on small capac...

Page 13: ...iii Eclipse AirHeat Burner V2 Design Guide 135 6 16 2010 Notes...

Page 14: ...Offered By Power Equipment Company 2011 Williamsburg Road Richmond Virginia 23231 Phone 804 236 3800 Fax 804 236 3882 www peconet com...

Reviews: