(2) Verify communication with Stormscope by confirming STORMSCOPE CONFIG page
appears as shown in
. If page appears different from
, re-check
settings in section C., and Stormscope installation and communication.
J.
Configure User Settings on AUX Pages.
(1) Rotate the GPS 400W power knob fully counter-clockwise, past the detent to the off
position. Wait for GPS 400W screen to go off, then rotate the power knob clockwise
past the detent to the on position.
(2) After powering on, the GPS 400W will start Self Test. Several screens of information
will be displayed. When a flashing OK? is displayed, press ENT.
(3) The INSTRUMENT PANEL SELF-TEST screen is displayed, with a flashing OK?.
Press ENT.
(4) A page from the NAV page group will be displayed (either the Map page or the
Satellite Status page). Rotate the large right knob until the AUX page group
indication is displayed in the lower right corner of the GPS 400W display. Refer to
(Figure 2).
(5) While on the first page of the AUX page group, press the small right knob to turn on
the cursor. Rotate the large right knob to select Crossfill and press ENT.
(6) Using the large right knob to select fields as necessary, the small right knob to make
selections, and ENT to confirm selections, set up the CROSSFILL configuration as
shown in
(7) Press the small right knob to return to the first AUX page after CROSSFILL
configuration is set. Press the small right knob again to dismiss the cursor on AUX
page 1.
(8) Rotate the small right knob to select the third page of the AUX page group (SETUP
1).
(9) While on the SETUP 1 page, press the small right knob to turn on the cursor. Press
ENT to select Airspace Alarms.
(10) Using the large right knob to select fields as necessary, the small right knob to make
selections and enter values, and ENT to confirm selections, set up the AIRSPACE
ALARMS configuration as shown in
.
(11) Press the small right knob to return to the SETUP 1 page after AIRSPACE ALARMS
configuration is set.
(12) Rotate the large right knob to select CDI / Alarms and press ENT.
(13) Using the large right knob to select fields as necessary, the small right knob to make
selections and enter values, and ENT to confirm selections, set up the CDI /
ALARMS configuration as shown in
.
(14) Press the small right knob to return to the SETUP 1 page after CDI / ALARMS
configuration is set.
(15) Rotate the large right knob to select Units / Mag Var and press ENT.
(16) Using the large right knob to select fields as necessary, the small right knob to make
selections, and ENT to confirm selections, set up the UNITS / MAG VAR
configuration as shown in
EA500 Aircraft Maintenance Manual — 06-117751
Temporary Revision No. 34-21
EFFECTIVITY: 0001-0262, POST SB 500-99-005; AND
0266-0267; ALL POST MB 500-31-018
34-50-10
CONFIG A
Page 208
Sep 30/20
© 2020 Eclipse Aerospace, Inc.