background image

2

Copyright

Copyright 2007 by Eclipse, inc. All rights reserved
worldwide. This publication is protected by federal
regulation and shall not be copied, distributed,
transmitted, transcribed or translated into any human or
computer language, in any form or by any means, to any
third parties, without the express written consent of
Eclipse, inc.

Disclaimer Notice

In accordance with the manufacturer’s policy of continual
product improvement, the product presented in this
brochure is subject to change without notice or obligation.

The material in this manual is believed adequate for the
intended use of the product. If the product is used for
purposes other than those specified herein, confirmation
of validity and suitability must be obtained. Eclipse
warrants that the product itself does not infringe upon any
United States patents. No further warranty is expressed or
implied.

Liability & Warranty

We have made every effort to make this manual as
accurate and complete as possible. Should you find errors
or omissions, please bring them to our attention so that we
may correct them. In this way we hope to improve our
product documentation for the benefit of our customers.
Please send your corrections and comments to our
Technical Documentation Specialist.

It must be understood that Eclipse’s liability for its product,
whether due to breach of warranty, negligence, strict
liability, or otherwise is limited to the furnishing of
replacement parts and Eclipse will not be liable for any
other injury, loss, damage or expenses, whether direct or

consequential, including but not limited to loss of use,
income, or damage to material arising in connection with
the sale, installation, use of, inability to use, or the repair
or replacement of Eclipse’s products. 

Any operation expressly prohibited in this manual, any

adjustment, or assembly procedures not recommended or 
authorized in these instructions shall void the warranty. 

Document Conventions

There are several special symbols in this document. You
must know their meaning and importance.

The explanation of these symbols follows below. Please
read it thoroughly.

How To Get Help

If you need help, contact your local Eclipse
representative. You can also contact Exothermics at:

5040 Enterprise Blvd.
Toledo, Ohio 43612 U.S.A.
Phone: 419-729-9726
Fax: 419-729-9705
http://www.eclipsenet.com

Please have the information on the product label available
when contacting the factory so we may better serve you.

This is the safety alert symbol. It is used to alert you to potential personal
injurt hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.

Indicates a hazardous situation which, if not avoided, will result in death
or serious injury.

Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.

Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.

Is used to address practices not related to personal injury.

Indicates an important part of text. Read thoroughly.

NOTE

NOTICE

CAUTION

WARNING

Summary of Contents for Exothermics Tubular 545

Page 1: ...Exothermics Tubular Heat Recuperators 3 20 2015 Installation Guide 545...

Page 2: ...ing of replacement parts and Eclipse will not be liable for any other injury loss damage or expenses whether direct or consequential including but not limited to loss of use income or damage to materi...

Page 3: ...Customer name Address City State Zip code Phone Fax Equipment Performance Estimate No Product Information Startup Record Model number Serial number Start Up Date Exhaust Volume Pressure Drop w c Exha...

Page 4: ...erator Training 5 Replacement Parts 5 Installation 6 Receipt of Heat Recuperator 6 Installation 6 Rigging 6 Thermal Expansion 7 Ductwork 7 Flange Details and Gaskets 8 Operation and Startup 8 Temperat...

Page 5: ...efforts dust created by sanding sawing grinding cutting and other construction activities could release crystalline silica Crystalline silica is known to cause cancer and health risks from the exposu...

Page 6: ...ial to reach elevated temperatures Personal protection must be considered when installing this unit Because the flange connections are considered HOT connections provisions for expansion are required...

Page 7: ...xpansion for the system Also it is recommended that permanent marks be placed on the support structure so thermal expansion can be monitored as part of a regular maintenance inspection program After s...

Page 8: ...nute Exceeding this rate may cause damage to the heat recuperator due to excessive thermal stress An approved high temperature limit control should be installed in the hot gas inlet airstream Control...

Page 9: ...ezing dirt dust or foreign materials and normal wear for that application are specifically excluded from this warranty Performance Warranty Performance figures or requirements if any must be addressed...

Page 10: ...er mm inch in 3 94 x 10 2 MJ Nm Btu ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 001 From...

Page 11: ...Notes ii...