background image

Exothermics Tubular Heat Recuperators, Installation Guide 545, 3/20/2015

9

Material and Workmanship:

Manufacturer warrants that the equipment proposed
herein of their manufacture shall be free of defects in
workmanship or materials for a period of one year from
date of shipment. Should any failure or defect appear
within one year of date of shipment, manufacturer shall
upon written notification of said failure and substantiation
that the equipment has been 

stored, installed

erected,

maintained, and operated in accordance with good
industry practice 

and in accordance with manufacturer's

instructions, correct such non-conformity by repair or

replacement, F.O.B

factory. This warranty does not cover

labor or transportation charges for 

the removal, exchange,

or reinstallation of the equipment.

Manufacturer shall not be responsible, nor shall allowance
be made, for work done, equipment furnished, or for
repairs or replacements made by the purchaser or others,
either with or without purchaser's approval, unless prior
written approval is made to the purchaser by the
manufacturer. Any unauthorized repairs or parts will void
the warranty.

Products or goods manufactured by others, supplied by
Exothermics, Inc. as a part of a 

system, are not covered

by this warranty. Exothermics, Inc

., however, 

will give their

customer 

the benefit of any such adjustment as it finally

obtains from that respective manufacturer of 

that

component or product

.

Freight damage is specifically excluded from this warranty
and is the responsibility of the 

purchaser and the carrier

.

Damage as a result of the effect of corrosion, erosion,
excessive heat, freezing, dirt, dust or foreign 

materials,

and normal wear for that application are specifically
excluded from this warranty

.

Performance Warranty

:

Performance figures or requirements, if any, must be
addressed in the quotation. Performance 

warranty, if any,

must be specifically covered in the quotation

Where no

performance figures are specified or warranted the
manufacturer assumes no responsibility for compliance or
noncompliance

.

THE FOREGOING WARRANTIES ARE EXCLUSIVE

AND IN LIEU OF ALL OTHER WARRANTIES, EXCEPT

THAT OF TITLE, AND EXOTHERMICS-ECLIPSE
HEREBY DISCLAIMS ALL OTHER WARRANTIES,
WHETHER WRITTEN, ORAL OR IMPLIED, IN FACT OR
IN LAW (INCLUDING ANY WARRANTY 

OF

MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE)

.

LIMITATION OF LIABILITY: IN NO EVENT SHALL THE
MANUFACTURER BE HELD RESPONSIBLE OR
LIABLE ON ANY CLAIM WHETHER IN CONTRACT,
TORT, NEGLIGENCE, STRICT LIABILITY, WARRANTY
OR OTHERWISE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL 

DAMAGES

RESULTING FROM THE PURCHASE OF SAID
EQUIPMENT

INCLUDING BUT NOT LIMITED 

TO

INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR
LABOR, LOST PROFITS, LOST PRODUCTION, LOST
SALES, INJURY TO PERSON OR PROPERTY OR ANY
OTHER INCIDENTAL LOSS OR DAMAGE.

THE REMEDIES OF THE PURCHASER SET FORTH
HEREIN ARE EXCLUSIVE AND THE LIABILITY OF THE
MANUFACTURER WITH RESPECT TO ANY
CONTRACT, OR ANYTHING DONE IN CONNECTION
THEREWITH, OR FROM THE MANUFACTURE, SALE,
DELIVERY, INSTALLATION OR USE OF SAID
EQUIPMENT COVERED BY OR FURNISHED UNDER
THIS PROPOSAL AND CONTRACT WHETHER IN
CONTRACT, TORT, WARRANTY, STRICT LIABILITY,
OR OTHERWISE, SHALL NOT EXCEED THE
PURCHASE PRICE ACTUALLY RECEIVED BY THE
MANUFACTURER FOR THE EQUIPMENT IN
QUESTION.

Having a policy of cont

i

nuous product 

i

mprovement,

Exothermics, Inc

reserves the right to change or alter

design or specification without notice.

Product Warranty

3

Summary of Contents for Exothermics Tubular 545

Page 1: ...Exothermics Tubular Heat Recuperators 3 20 2015 Installation Guide 545...

Page 2: ...ing of replacement parts and Eclipse will not be liable for any other injury loss damage or expenses whether direct or consequential including but not limited to loss of use income or damage to materi...

Page 3: ...Customer name Address City State Zip code Phone Fax Equipment Performance Estimate No Product Information Startup Record Model number Serial number Start Up Date Exhaust Volume Pressure Drop w c Exha...

Page 4: ...erator Training 5 Replacement Parts 5 Installation 6 Receipt of Heat Recuperator 6 Installation 6 Rigging 6 Thermal Expansion 7 Ductwork 7 Flange Details and Gaskets 8 Operation and Startup 8 Temperat...

Page 5: ...efforts dust created by sanding sawing grinding cutting and other construction activities could release crystalline silica Crystalline silica is known to cause cancer and health risks from the exposu...

Page 6: ...ial to reach elevated temperatures Personal protection must be considered when installing this unit Because the flange connections are considered HOT connections provisions for expansion are required...

Page 7: ...xpansion for the system Also it is recommended that permanent marks be placed on the support structure so thermal expansion can be monitored as part of a regular maintenance inspection program After s...

Page 8: ...nute Exceeding this rate may cause damage to the heat recuperator due to excessive thermal stress An approved high temperature limit control should be installed in the hot gas inlet airstream Control...

Page 9: ...ezing dirt dust or foreign materials and normal wear for that application are specifically excluded from this warranty Performance Warranty Performance figures or requirements if any must be addressed...

Page 10: ...er mm inch in 3 94 x 10 2 MJ Nm Btu ft standard 26 86 From To Multiply By kiloPascals kPa millibar mbar 10 meter m millimeter mm 1000 millibar mbar kiloPascals kPa 0 1 millimeter mm meter m 0 001 From...

Page 11: ...Notes ii...

Page 12: ......

Reviews: