6
©2009 Eco-Orlan USA LLC. All Rights
Reserved
.
Revised August 2009.
Parameters
units
Paxo
®
18
Paxo
®
25
Paxo
®
40
Paxo
®
60
Paxo
®
80
Power range
Btu
75k
85k
137k
205k
275k
Power
kW
4-18
5-31
8-40
15-60
25-80
Efficiency
%
85
91
91
91
91
Weight
Lb
1020
1280
1390
2070
2712
Height
A inch
44
51.75
62
62
60.5
Height of heating water outlet
B inch
47.6
48.5
56
58
60
Height of heating water inlet
(Flange)
C inch
8.5
8.3
6.0
7.9
7.9
Height of outlet valve
D inch
5.7
5.1
5.7
5.1
5.1
Height of chimney flue
E inch
34.3
37.4
50
45.7
45.7
Width including handle
F inch
24.8
29.25
29.25
35.25
35.25
Width including casing
G inch
24
27
27
32.5
32.5
Depth
H inch
37.8
41
40.75
51.5
65
Hot water outlet
I inch
13.4
12.6
12.6
24.0
24.0
Diameter of chimney flue
J inch
8.0
8.0
8.0
8.0
8.0
Width with coil
K inch
26
28.3
28.3
33.9
33.9
Height of coil connection
L inch
39
43.3
52.4
51.6
51.2
Coil outlet
M inch 10.2
5.9
10.2
14.4
12.4
Diameter of feeding and return
ferrule
Q inch
2
2
2
2
2
Diameter of the coil ferrule
R inch
¾”
¾”
¾”
¾”
¾”
Diameter of the drain valve
S inch
0.5
0.5
0.5
0.5
0.5
Water capacity
Gal
14.5
20
25
47
54
Loading chamber capacity
(gasification)
ft³
4.1
6.5
10.9
16.4
Power consumption
W
50
50
50
100
100
Maximum length of logs
inch
20
20
20
25
39
Maximum log diameter
inch
7
7
7
7
7
Moisture content of wood:
-recommended
%
15-25
-acceptable
%
15-35
Average flue gas temperature
°F
340
Maximum working pressure
PSI
25
Required chimney draught
Pa
15-20 Pa = .06-.08 inches of water
Voltage/frequency
V/Hz
120V/60Hz