background image

P a g e

 | 

 

Version10- March 2017 

Eco Pacific Pty Ltd 

 

IOS MANUAL 

 

Installation, Operation, and Service Instructions  

 

Fresh Filtered Air Ventilators with Efficient Heat/Cool Recovery from Indoor Air 

 

 

 

Models:  AussiVent / EcoVent/ FreshVent  

 

 

Please read these instructions prior to installation 

 

 

 

 

 

 

Manufactured by Eco Pacific Pty. Ltd., Australia  

 

www.ecopacific.com.au

 

 

Email

sales@ecopacific.com.au

 

 

Tel: +61-3-9706 6228 or 1300ecopac 

 

 

Summary of Contents for AussiVent

Page 1: ...ions Fresh Filtered Air Ventilators with Efficient Heat Cool Recovery from Indoor Air Models AussiVent EcoVent FreshVent Please read these instructions prior to installation Manufactured by Eco Pacifi...

Page 2: ...e to temperature difference With an energy recovery effectiveness of up to 85 the HRV delivers fresh filtered air at near room temperatures in all seasons irrespective of outdoor temperatures The HRV...

Page 3: ...mance and pressure drop Report ref 30S 15 0158 TRP 392476 1 2016 1 3 MODELS AND THEIR DISTINCTIONS There are three models which all utilise a common thermal transfer process The fresh air ventilator i...

Page 4: ...le namely FV80 and FV120 Illustration 1 Physical appearance of the three models with their dedicated controls 1 4 FILTER BOX The Filter Box is the same for all the models The filter cassette can be cu...

Page 5: ...FLOWS AV80 EV80 and FV80 provide air flows of 80 l s at 100 Pa external static pressure ESP AV120 EV120 and FV120 provide air flows of 120 l s at 100 Pa ESP Note the Filter Sensor is fitted to the sta...

Page 6: ...y docket with photo evidence attached and be sent to the local agent dealer The damage should be claimed within three days from inspection The manufacturer supplying the HRV relies on the dealer contr...

Page 7: ...lated Flexi solid ducts are recommended for the Return Air from indoor to the unit Inlet outlet collar sizes for ducting AussiVent and EcoVent models AV80 AV120 EV80 and EV120 are fitted with 6 inch c...

Page 8: ...Eco Pacific Pty Ltd Use the M5 bolts 2 each side on the wall brackets Put the HRV on the bracket slide it through and fasten it on to the brackets using two M5 bolts each side threading from the botto...

Page 9: ...and insects The indoor air inlet should also be fitted with a wire mesh filter inside the grille to protect the heat exchanger from dirt scaling and insects and should be cleaned monthly 3 4 SERVICE...

Page 10: ...aggravates the ripening process occasionally culminating with rotting of the Produce The FreshVent HRV can remove the ethylene and bring fresh filtered air into the cold room to slow down the ripenin...

Page 11: ...ir The drain pipe should have gravity fall of at least one inch for every 3 meter length of the drain pipe to the nearest down pipe to the ground Comply with local authorities in regards to drain disc...

Page 12: ...P a g e 12 Version10 March 2017 Eco Pacific Pty Ltd Illustration 8 Wiring diagram for AussiVent and FreshVent models with AV fans...

Page 13: ...air tight 9 Check the wall controller is mounted firmly on the wall with clear passage to the power cord and tele connector without interfering with its surrounding Make sure the wall controller s vic...

Page 14: ...P a g e 14 Version10 March 2017 Eco Pacific Pty Ltd Illustration 9 wiring diagram for EcoVent with AV fans...

Page 15: ...is free to allow air flow Check outdoor air inlet in the filter Clean the filter Check fan motor operation 3 HRV is running noisy Check the fan wheel is not touching the cabinet if yes call the servic...

Page 16: ...ower from the power outlet To access a motor remove the two base screws and the two lid screws of that motor end of casing Lift the side panels slightly above the base and pull out this end panel gent...

Page 17: ...on10 March 2017 Eco Pacific Pty Ltd Illustration 12 Filter side power and wall controller connections for motor and the H X Illustration 13 Base screws 2 at each end to separate the side panels to ser...

Page 18: ...ed by a faulty installation or maintenance not in accordance with the recommended ECO PACIFIC maintenance schedule Eco Pacific Pty Ltd reserves the right to void the Warranty where the agreed payment...

Reviews: