Chapter I Page 4
I.2. Hydraulic connections.
The connection between the various components is made with the tubes supplied with the
unit, as shown in the diagram in Chapter I Pages 1 and 2.
The two suction connections between the points described below are made using the
transparent tube
Ø
20
•
Lower three way valve inlet (2) and sea cock valve seawater intake (1).
•
Sea strainer outlet (3) and pump inlet (4).
The connection between the boat pressurized water intake to the carbon filter inlet (13) and
the connections between the carbon filter outlet and the three way valve inlet (2), have to be
made with the
Ø
15 blue tube
As a general rule, the tube sections should be as short and as straight as possible to
avoid unnecessary pressure drop, and the connections should be completely airtight so
that air does not enter the circuit during water suction.
The remaining seawater circuit sections are made with blue tube
Ø
15 (maximum pressure
20 bar) It is a special tube developed to work with up to 20 bar, and it is not
recommended to be replaced with a different one (even of similar characteristics)
To make the connections proceed as indicated below:
•
Pump outlet (4) and 5-micron pre-filter inlet (6).
•
Pre-filter outlet (6) and the high-pressure pump (8) inlet elbow (E).
•
Outlet elbow (S) of the pressure amplifier pump (8) and the brine outlet (15).
The referred elbows marked as E and S are located in the back / lower part of the high
pressure pump (8)
To connect the high pressure pump (ETD) with the R.O. membrane vessel proceed to use a
high pressure hose (blue with stainless steel terminals) from the stainless steel connection
located in the brine outlet, marked with the letter (P) in the back side of the high pressure
pump (8), with the stainless steel elbow located in the R.O. membrane vessel , marked as
ENTRADA (E) Then proceed to connect link the R.O. membrane vessel elbow marked as
SALIDA (S) to the stainless steel adaptor marked as (R) located at the high pressure
pump(8).by using the other high pressure hose(blue with stainless steel connections).
By using the
Ø
8 polyamide tube, connect the end cap plastic adaptor (10), located in the
membrane vessel inlet with the lower flow meter connector (12) as well as with the three
way valve outlets (11), connect the left adaptor to the main tank adaptor (14), and the right
adaptor to the produced fresh water outlet (17).
Summary of Contents for WATER-PRO MODULAR B-60
Page 4: ...CHAPTER I INTALLATION OPERATION AND MAINTENANCE ...
Page 14: ...CHAPTER II STORAGE AND CLEANING ...
Page 19: ...CHAPTER III PARTS LISTING EXPLODED VIEW OF THE ST 15 CERAMIC ECO SISTEMS PUMP ...
Page 23: ...CHAPTER IV FILTERS AND MEMBRANE REPLACEMENT ...
Page 26: ... F L O W E N T R A D A S A L I D A 1 2 3 7 M A X 9 3 5 m m Chapter IV Page 3 ...