4. Insert the ESP filters back into the unit. 

NOTE: 

The  product  may  experience some discoloration on  ESP filters  over  time. 

This is normal and does not affect the performance of the product in any way. 
 

CLEANING AND MAINTENANCE THE UNIT 

1. The unit should be checked at least once every week and the pre-filter should be 

cleaned  every  week.  More  frequent  cleaning  may  be  required  depending  upon 
environmental conditions.   

2. Clean the pre-filter as 

REMOVING/CLEANING/INSTALLING PRE-FILTERS

3. Clean the ESP filters every 2-3 weeks as 

REMOVING/CLEANING/ 

INSTALLING ESP FILTERS

4. If ESP Reset Indicator illuminates, you need to turn off the unit and unplug it, 

then check or clean the ESP filters as

 REMOVING/CLEANING/

 

INSTALLING ESP FILTERS

.

 

5. Use a clean, dry, soft cloth to wipe the external surface of unit. 

NOTE: 

Do not stick any foreign objects or your fingers inside the unit. 

CAUTION: 

Do not use gasoline, benzine, thinner, harsh cleaners, etc., as 

they will damage the product. NEVER use ALCOHOL OR SOLVENTS.

 

 
SAFETY FEATURE 

1. A thermal overload protector is built in to prevent overheating. 
2. When an overheat temperature is reached, the product will be automatically shut 

off. It can only resume operation when the user resets the unit. 

To Reset Heater: 

1. Unplug the unit and wait 10 minutes for the heater to cool down. 
2. After the heater has cooled down, plug the unit into an exact AC electrical outlet 

and follow the operation instructions described in this manual.

 

 
 
 
 
 
 

Summary of Contents for ATI-HPE-PD

Page 1: ...in 1 AIR PURIFIER INFRARED ZONE HEATING SYSTEM with ELECTROSTATIC COLLECTOR AND HEATER OWNER S MANUAL Model No ATI HPE PD www advancedtechinfrared com READ AND SAVE THESE IMPORTANT SAFETY INSTRUCTION...

Page 2: ...areas To avoid fire hazard NEVER put the cord under rugs near heat registers radiator stoves or heaters 4 To protect against electrical hazards DO NOT immerse in water or other liquids Do not use nea...

Page 3: ...in heating mode To avoid burns do not let bare skin touch hot surfaces Always use handle when moving this appliance Keep combustible materials such as furniture pillows bedding papers clothes and cur...

Page 4: ...electric shock DO NOT use this air purifier with any solid state speed control device 24 The ESP filters have many edges and areas that can trap water The ESP filters should be completely dry before...

Page 5: ...of reach from children or infirm persons Do not let them use the appliances without supervision PRE OPERATING INSTRUCTIONS 1 Carefully remove your air purifier from the gift box and the bag 2 Select...

Page 6: ...xchange of temperature 4 Upon turning the air purifier on the unit will be in PU HI Purify High mode 5 Pressing Mode Button at this point will set the air purifier into PU LO Purify Low mode 6 Pressin...

Page 7: ...yed temperature will begin to flash 2 Press the Increasing Button to increase the desired set temperature or press the Decreasing Button to decrease the desired set temperature For Celsius the tempera...

Page 8: ...ith the Remote Control work identically to the manual controls Figure 2 1 Install two AAA batteries as shown in Figure 2 2 Do not mix old and new batteries Do not mix alkaline standard carbon zinc or...

Page 9: ...ure 3 1 Turn off and unplug the unit 2 Press the spring buttons and take off the air inlet covers from the unit 3 With the air inlet covers removed grip the handles of ESP filters and pull them out Wa...

Page 10: ...ff the unit and unplug it then check or clean the ESP filters as REMOVING CLEANING INSTALLING ESP FILTERS 5 Use a clean dry soft cloth to wipe the external surface of unit NOTE Do not stick any foreig...

Page 11: ...rical outlet 2 Check to be sure the ESP filters is firmly seated in place 3 Check to be sure the air inlet covers are latched firmly in place NOTE IF YOU CONTINUE TO EXPERIENCE A PROBLEM PLEASE RETURN...

Page 12: ...10...

Reviews: