background image

 

- 2 - 

 

Please read this manual carefully before use!

 

Thank  you  for  purchasing  our  200W  COB  WHITE  LED  PAR64.  Please  read  user 
guide for safety and operations before using. Keep this manual for future reference.   
 

1. Safety Instructions 

 

 

  Please  keep  this  User  Manual  for  future  consultation.  If  you  sell  the  fixture  to 

another user, be sure that they also receive this intruction booklet. 

  Please  unpack  and  check  carefully  there  is  no  transportation  damage  before 

using the fixture. 

  Please disconnect main power before servicing and mantenance. 

  The unit must be installed in a location with adequate ventilation, at least 50cm 

from adjacent surfaces.Be sure that no ventilation slots are blocked. 

  The maximum ambient temperature is Ta:40

°

C. DO NOT operate it where the 

temperature is higher than this.   

  DO NOT connect the device to any dimmer pack.   

  The housing must be replaced if they are visibly damaged.   

  Unit  surface  temperature  may  reach  up  to  85

°

C.  Don

’t  touch  the  housing 

bare-hand during its operation. Turn off the power and allow about 15 minutes for 
the unit to cool down before replacing or serving.   

  There are no user serviceable parts inside the fixture. Do not open the housing or 

attempt  any  repairs  by  yourself.  In  the  unlikely  event  your  fixture  may  require 
service, please contact your nearest dealer. 

  In the event of serious operating problem, stop using the fixture   

Immediately.  Never  try  to  repair  the  fixture  by  yourself.  Repairs  carried  out  by 
unskilled  people  can  lead  to  damage  or  malfunction.  Please  contact  the  nearest 
authorized technical assistance center. Always use the same type spare parts. 
 

2. Safety Instructions 

 

  1/2/3 Channel Mode; 

  Dimmer, Strobe; 

  Ideal for Professional stages, Concerts, Clubs, Discotheques, Mobile Djs, etc. 

 

Input Voltage:   

                            AC100V~240V,50/60Hz 

 

Total Power consumption:

        230W 

Summary of Contents for PAR LED COB WW

Page 1: ... 1 200W WHITE LED PAR64 PAR LED COB WW 200W User Manual ...

Page 2: ...connect the device to any dimmer pack The housing must be replaced if they are visibly damaged Unit surface temperature may reach up to 85 C Don t touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by...

Page 3: ... the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professional...

Page 4: ...ctions press MENU button until the required one is shown on the display Select the fuction by ENTER button Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will return to the main functions without any change after idling 8 seconds automatically Back to the functions without any change press MENU button The main function are shown...

Page 5: ...Hz 5000Hz 10K 15K 20K 25K Gamma correction enter NO 2 2 2 2 4 2 6 2 8 Slnd enter Mast master Sl 1 slave Lost enter blac hold auto Manu enter d000 d255 manual dimmer 0 255 Tenp temperature enter 00C 90C Led set backlight enter on off disp display reverse enter on off Fhrs working hours enter total working hour Ver software version enter software version defa set default enter default ...

Page 6: ...el Mode Channel Function Value Details CH1 Dimmer 000 255 Master Dimmer 0 100 CH2 Dimmer_Fine 000 255 Fine dimmer CH3 Strobe 000 015 Strobe on 016 095 Strobe 1HZ 25HZ Slow Fast 096 175 Strobe 1HZ Slow Fast 176 255 Random Strobe 8 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixture does not work no ligh...

Page 7: ...or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 9 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with ...