(Nenu) 

Freq (dimmer frequency)  enter    +/- 

900Hz 

 
 
 
 

Press 

ENTER 

to 

confirm 

(save 

and exit)   

 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Press 

ENTER 

to 

confirm 

(save 

and exit) 

1000Hz 

1100Hz 

1200Hz 

1300Hz 

1400Hz 

1500Hz 

2500Hz 

4000Hz 

5000Hz 

10K 

15K 

20K 

25K 

Gamma correction 

enter    +/- 

NO 

2.2 

2.4 

2.6 

2.8 

Slnd 

enter  +/- 

Mast    (master) 

Sl 1    (slave) 

Lost 

enter    +/- 

blac 

hold   

auto   

Manu 

enter  +/- 

d000-d255                                 

( manual dimmer 0-255) 

Tenp (temperature) 

enter 

 

00C-90C   

Led (set backlight

 

enter 

 

on       

off             

disp (display reverse)  enter 

 

on   

off   

Fhrs (working hours) 

enter 

 

total working hour 

Ver (software version)  enter 

 

software version 

defa (set default)   

enter 

 

default 

 

 

 

 

 

 

 

Summary of Contents for PAR LED COB WW

Page 1: ... 1 200W WHITE LED PAR64 PAR LED COB WW 200W User Manual ...

Page 2: ...connect the device to any dimmer pack The housing must be replaced if they are visibly damaged Unit surface temperature may reach up to 85 C Don t touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by...

Page 3: ... the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professional...

Page 4: ...ctions press MENU button until the required one is shown on the display Select the fuction by ENTER button Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will return to the main functions without any change after idling 8 seconds automatically Back to the functions without any change press MENU button The main function are shown...

Page 5: ...Hz 5000Hz 10K 15K 20K 25K Gamma correction enter NO 2 2 2 2 4 2 6 2 8 Slnd enter Mast master Sl 1 slave Lost enter blac hold auto Manu enter d000 d255 manual dimmer 0 255 Tenp temperature enter 00C 90C Led set backlight enter on off disp display reverse enter on off Fhrs working hours enter total working hour Ver software version enter software version defa set default enter default ...

Page 6: ...el Mode Channel Function Value Details CH1 Dimmer 000 255 Master Dimmer 0 100 CH2 Dimmer_Fine 000 255 Fine dimmer CH3 Strobe 000 015 Strobe on 016 095 Strobe 1HZ 25HZ Slow Fast 096 175 Strobe 1HZ Slow Fast 176 255 Random Strobe 8 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixture does not work no ligh...

Page 7: ...or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 9 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with ...

Reviews: