7. DMX512 configuration 

Channel Mode: 

1 Channel Mode 

Channel   

Function 

Value         

Details 

CH1 

Dimmer   

000-255 

Master Dimmer 0-100% 

2 Channel Mode 

Channel   

Function 

Value         

Details                                                                                   

CH1 

Dimmer   

000-255 

Master Dimmer 0-100%   

CH2 

Strobe 

000-015 

Strobe on 

016-095 

Strobe 

1HZ-25HZ Slow-Fast

 

096-175 

Strobe 

1HZ Slow-Fast

   

176-255 

Random Strobe   

3 Channel Mode 

Channel   

Function 

Value         

Details                                                                                   

CH1 

Dimmer 

000-255 

Master Dimmer 0-100%   

CH2 

Dimmer_Fine 

000-255 

Fine dimmer 

CH3 

Strobe   

000-015 

Strobe on   

016-095 

Strobe 

1HZ-25HZ Slow-Fast

 

096-175 

Strobe 

1HZ Slow-Fast

   

176-255 

Random Strobe   

 

8. Troubleshooting 

Following  are  a  few  common  problems  that  may  occur  during  operation.  Here  are 
some suggestions for easy troubleshooting: 
 

A. The fixture does not work, no light 

1. Check the connection of power and main fuse. 
2. Measure the mains voltage on the main connector. 
 

B. Not responding to DMX controller 

Summary of Contents for PAR LED COB WW

Page 1: ... 1 200W WHITE LED PAR64 PAR LED COB WW 200W User Manual ...

Page 2: ...connect the device to any dimmer pack The housing must be replaced if they are visibly damaged Unit surface temperature may reach up to 85 C Don t touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs by...

Page 3: ... the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be fixed by professional...

Page 4: ...ctions press MENU button until the required one is shown on the display Select the fuction by ENTER button Use DOWN and UP button to change the mode Once the required mode has been selected press ENTER button to setup or it will return to the main functions without any change after idling 8 seconds automatically Back to the functions without any change press MENU button The main function are shown...

Page 5: ...Hz 5000Hz 10K 15K 20K 25K Gamma correction enter NO 2 2 2 2 4 2 6 2 8 Slnd enter Mast master Sl 1 slave Lost enter blac hold auto Manu enter d000 d255 manual dimmer 0 255 Tenp temperature enter 00C 90C Led set backlight enter on off disp display reverse enter on off Fhrs working hours enter total working hour Ver software version enter software version defa set default enter default ...

Page 6: ...el Mode Channel Function Value Details CH1 Dimmer 000 255 Master Dimmer 0 100 CH2 Dimmer_Fine 000 255 Fine dimmer CH3 Strobe 000 015 Strobe on 016 095 Strobe 1HZ 25HZ Slow Fast 096 175 Strobe 1HZ Slow Fast 176 255 Random Strobe 8 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixture does not work no ligh...

Page 7: ...or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 9 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with ...