ETS 73
0548-990-51---60g_2019.10.indd
0548-990/52g
Page 55 of 98
Mounting and operating instructions
5.4.3
Motorized lock with separate evaluation control/power pack
The motorized lock is equipped with a separate evaluation control and a separate power pack
ensuring the power supply. The swing door drive mechanism is configured as the Master and
transmits a voltage free impulse to the control unit of the motorized lock for releasing the latter.
Note:
Remove the jumper between terminals 28 and 29 on the control PCB of the swing door
drive mechanism.
Designations
Terminals
Remarks
Swing door drive mechanism 1
24 VDC
3
GND
29
EL-COM
30
EL-NO
28
GND
32
EL-Fb
-
MTSFlip Lock access
Control unit (AWS) 1.1
-
-
X8 / 5
X8 / 6
X1 / 36
X1 / 37
CONFIG
EL-Fb = N.C.
PARAMETER
TDelay = 0
MTS anti-panic lock M-9300
with control unit (KABA
x-lock)
-
-
X6 / 2
X6 / 5
X3 / 20
X3 / 21
CONFIG
EL-Fb = N.O.
PARAMETER
TDelay = 0
Fuhr autotronic 834
Fuhr autotronic 834P
(anti-panic function for fire
safety doors)
Fuhr multitronic 881
Fuhr multitronic 881GL
with control housing, top
hat rail control or control
box
-
-
9
10
3
4
CONFIG
EL-Fb = N.C.
PARAMETER
TDelay = 0
Dorma M-SVP 3000 with
control unit
-
-
9
10
3
4
CONFIG
EL-Fb = N.C.
PARAMETER
TDelay = 0
effeff
Multiple motor locking 519
with control module UII and
power pack 1003-24-4-10
(24 V/4 A)
-
-
7
15c
29
28
CONFIG
EL-Fb = N.C.
Control module UII
Attention:
With fire-rated doors, it is
mandatory to use the fire-protection
module 519ZBFS!
G-U
Master
Slave
B-1893x / B-1993x
with control unit B-54900-
01-3-9 and power pack
B 5570 0401
-
-
-
-
+24V V2
I1
I2
42
42
52
52
CONFIG
EL-Fb = N.C.
PARAMETER
TDelay = 0
Attention:
With fire-rated doors, it
is mandatory to use the emergency
standby power system B-54903-23-
3-9!