ETS 73
0548-990-51---60g_2019.10.indd
< 5
>
m E50
KEY
s E52
>##<
E50
0548-990/52g
Page 71 of 98
Mounting and operating instructions
On the
1st level
, the following information is shown on the display:
1st display line:
The door position is represented by means of the arrows (><). Alternatively, the motion-relevant
opening and safety signals are displayed. The double hash signs (##) indicate that the door is
locked. In the open position the hold-open time is shown in the form of a countdown.
Display of the door position:
<REF?>
Waits for reference switch
< ?? >
Unknown
><
Closed
>##<
Closed and locked
<< >>
Opening
< >
Open
>> <<
Closing
==
Stopping
Display of the door control:
OEO
Opening element outside
OEI
Opening element inside
KEY
Opening element NIGHT
SES
Safety element Stop
SER
Safety element Reversing
SEF
Safety element Force (obstacle detection)
EMY
Emergency element
PUGO
Push-and-Go
2nd display line:
• at the bottom, left-hand side, the presently enabled operating mode is
displayed (a frame around the symbol indicates the overriding operat
-
ing mode).
• (m) means closing sequence - Master
• (s) means closing sequence - Slave
• (w) means interlock
• at the bottom, right-hand side, the presently active errors are dis
-
played.
By means of OK you can switch over from the first to the second level.
For all the menus of the following list, exiting is possible by remaining on the OK key, or by means
of the menu item ESC.
On the
2nd level
, the following menus are available:
PARAMETER
Setting the motional parameters
• A changed parameter value is shown by a flashing display.
Press OK in order to validate the change.
CONFIG
Setting the functionalities
• A changed parameter value is shown by a flashing display.
Press OK in order to validate the change.
DOUBLE DOOR
Setting the closing sequence and interlock function
• A changed parameter value is indicated by a flashing display.
In order to validate the change, OK must be pressed.