ETS 73
0548-990-51---60g_2019.10.indd
80
Ø10,4 x 90°
8
28
6
M6
Ø5,5
R2
6
6
6
68
27,5
28
12,5
8
17,5
45
14
0548-990/52g
Page 92 of 98
Mounting and operating instructions
13.3
Open position stop piece integrated in the drive mechanism
Attention:
It is recommended that a stop piece be mounted by the customer. This stop piece pre
-
vents the door leaf from being damaged in the manual operating mode. As an option,
an open position stop piece can be integrated into the drive mechanism itself.
13.4
Connection plate for wooden door leaf (normal rods)
The connection plate is mounted below the door connection angle of the normal rod assembly
and screwed down by means of countersunk chipboard screws 5 x 30.
0548-106 Normal rod
0548-175 Normal rod RS
Packing unit
0549-115
1 Connection plate
0549-341
5 Screws 5 x 30
4082-359
2 Screws M6 x 8
4015-307
black
cataphoretic painting