Mounting and operating instructions
13.1.3
Operating modes
With the D-BEDIX, the following operating modes can be selected by means of the corresponding
symbols:
AUTOMATIC
Automatic operation. The installation can be locked.
NIGHT
The installation is locked
1
. As opening commands, only the key-operated impulse
switch is accepted.
The delayed switchover to the operating mode NIGHT can be activated by means
of parameter TdNigt. Function: If the program selector switch is changed to the
operating mode NIGHT from any random operating mode, the internal radar will still
remain active during the programmed time TdNigt (EXIT).
OPEN
The installation is opened and remains in the open position.
MANUAL
The installation stops. The swing door leaf is released and can be manually opened
and closed.
EXIT
One-way traffic from inside towards the outside.
The installation is locked
2
(shop closing switching mode).
1
Provided that the locking mechanism (optional) is installed.
2
Each operating mode can be locked (this is configurable).
13.1.4
Display of the door position
The following door positions are represented onthe D-BEDIX display:
<REF?> Waits for reference switch
< ?? > Unknown
><
Closed
>##<
Closed and locked
<< >> Opening
< > Open
>> << Closing
==
Stopping